The efficacy and safety of ultrasonic bone scalpel for removing retrovertebral osteophytes in anterior cervical discectomy and fusion: A retrospective study.

Yao Zhi, Zhang Shishuang, Liu Weijun, Wei Mengcheng, Fang Weizhi, Li Qingbo, Cai Lei, Wang Zhengkun, Zhou Chuankun, Zhou Yichi

СтатьяПеревод в очереди

Аннотация

In this study, we present a novel surgical method that utilizes the ultrasonic bone scalpel (UBS) for the removal of large retrovertebral osteophytes in anterior cervical discectomy and fusion (ACDF) and evaluate its safety and efficacy in comparison to the traditional approach of using high-speed drill (HSD). A total of 56 patients who underwent ACDF for retrovertebral osteophytes were selected. We recorded patients' baseline information, operation time, intraoperative blood loss, complications, JOA and VAS scores, and other relevant data. The mean operation time and the mean intraoperative blood loss in the UBS group were less than those in the HSD group (P < 0.05). Although both groups exhibited considerable improvements in JOA and VAS scores following surgery, there was no statistically significant difference between the two groups (P > 0.05). Additionally, no significant disparities were found in bone graft fusion between the two groups at 6- and 12-months postsurgery. Notably, neither group exhibited complications such as dura tear or spinal cord injury. Our study found that the use of UBS reduced operative time, minimized surgical bleeding, and led to clinical outcomes comparable to HSD in ACDF. This technique offers an effective and safe method of removing large retrovertebral osteophytes.

Для цитирования: Yao Zhi, Zhang Shishuang, Liu Weijun, Wei Mengcheng, Fang Weizhi, Li Qingbo, Cai Lei, Wang Zhengkun, Zhou Chuankun, Zhou Yichi. The efficacy and safety of ultrasonic bone scalpel for removing retrovertebral osteophytes in anterior cervical discectomy and fusion: A retrospective study.. Scientific reports. 2024. DOI: 10.1038/s41598-023-50545-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.