Wearable Sensor-Derived Gait Parameters Across Self-Reported Physical Activity Levels in Individuals With Knee Osteoarthritis and Healthy Controls: Pilot Cross-Sectional Validation Study.
Аннотация
BACKGROUND
Wearable inertial measurement units (IMUs) offer scalable, objective gait assessment, but detailed stride-level validation against motion capture and their ability to reflect physical activity (PA)-related gait differences in knee osteoarthritis (KOA) remain incompletely characterized.
OBJECTIVE
This study aimed to evaluate the technical validity of foot-mounted IMU-derived gait parameters compared with optical motion capture in individuals with KOA and healthy controls. As a secondary exploratory aim, we assessed whether IMU-derived gait parameters differed across self-reported PA levels.
METHODS
In this pilot cross-sectional validation study, 20 participants (KOA: n=10, 50%; healthy controls: n=10, 50%) completed 3 standardized walking conditions (self-paced, fast-paced, and endurance-equivalent). IMU-derived gait parameters were compared with motion capture at the stride level (≥5000 strides) using Pearson correlation, intraclass correlation coefficients (ICCs), mean absolute error, root mean square error, and Bland-Altman analysis. Participants completed the Stanford Brief Activity Survey to categorize PA level. Secondary analyses emphasized effect sizes and 95% CIs given the pilot design. Feasibility was assessed by protocol completion, data completeness, and tolerability.
RESULTS
IMU-derived gait speed demonstrated strong agreement with motion capture (r=0.99; ICC=0.98, 95% CI 0.95-0.99; mean absolute error=0.07 m/s; bias=0.01 m/s; 95% limits of agreement -0.14 to 0.16 m/s). Stride length and cadence showed similarly high agreement (ICC range 0.96-0.97). All participants completed the protocol with minimal adverse events. Exploratory analyses suggested that participants reporting higher PA demonstrated directionally faster gait speed and longer stride length, with small-to-moderate effect sizes, whereas inactive participants exhibited higher stance-related rhythm parameters.
CONCLUSIONS
Foot-mounted IMUs demonstrated strong stride-level agreement with motion capture across walking conditions, supporting technical validity in both KOA and healthy populations. Exploratory findings suggest that wearable-derived gait parameters may reflect activity-related differences; however, larger longitudinal studies are required to confirm these preliminary signals.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.