MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13018-024-05213-w

Медицинская библиотека · Journal of orthopaedic surgery and research · 2024

Robot-assisted technique can achieve accurate screw placement in four-corner fusion and reduce operative difficulty: a cadaver study.

Wang Zhixin, Liu Bo, Yi Zhe, Xu Ke, Jia Shijie, Wang Qianqian, Yin Yaobin

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The purpose of this study is to explore the feasibility and accuracy of a robot-assisted technique in four-corner fusion compared with traditional freehand operation.

METHODS

Twenty cadaver specimens were randomly assigned to the robot-assisted group and freehand groups. Three screws were placed percutaneously to fix the capitate-lunate joint, lunate-triquetrum joint, and triquetrum-hamate-capitate joint in each specimen by robot-assisted or freehand technique. The offset between the actual and planned screw positions was determined by merging the images of intraoperative and postoperative CT scans in the robot-assisted group. The centrality of the screw, time-consuming, drilling attempts, and radiation exposure were compared between the two groups.

RESULTS

The mean offset between the actual and planned screw position was 1.09 (SD: 0.56) mm. The offset at the start point of the screw was significantly lower than that at the endpoint. There was no significant difference in the centrality of the screws, surgical time between the two groups. The number of drilling attempts and the radiation dose received by surgeons were significantly lower in the robot-assisted group.

CONCLUSIONS

Although there was no significant difference in screw centrality between the two groups, the slight offset between the actual and planned screw positions confirmed the feasibility of the robot-assisted technique in four-corner fusion. The robot-assisted technique has advantages in reducing the difficulty of surgery and protecting the surgeon from exposure to large doses of radiation.

Для цитирования: Wang Zhixin, Liu Bo, Yi Zhe, Xu Ke, Jia Shijie, Wang Qianqian, Yin Yaobin. Robot-assisted technique can achieve accurate screw placement in four-corner fusion and reduce operative difficulty: a cadaver study.. Journal of orthopaedic surgery and research. 2024. DOI: 10.1186/s13018-024-05213-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.