DOI 10.1080/14796678.2026.2689050

Медицинская библиотека · Future cardiology · 2026

Wearable devices for atrial fibrillation: diagnostic and screening roles of ECG and PPG-A systematic review.

Bin Rashid Abdullah, Aslam Eman, Ashraf Isha, Mubeen Tehreem, Mubeen Amen, Zakriya Hamna, Amjad Maryam

СтатьяСистематический обзорПеревод в очереди

Аннотация

OBJECTIVE

Atrial fibrillation (AF) is a major predictor of heart failure, stroke, and mortality. Traditional Holter monitors and event recorders are limited by short recording times. Wearable electrocardiographic (ECG) and photoplethysmographic (PPG) devices enable continuous monitoring and large-scale AF screening. This review assesses their diagnostic performance, clinical usefulness, and implementation challenges.

METHODS

Following PRISMA guidelines, PubMed, Embase, and Web of Science were searched for studies from 2010-2025. Included studies had ≥30 participants and reported AF detection accuracy or clinical outcomes. Studies evaluating PPG devices required ECG verification as the reference standard.

RESULTS

Wearable ECG patches showed high sensitivity (92-98%) and specificity (85-97%) and detected more AF episodes than short-duration Holter monitoring. PPG-based smartwatches demonstrated moderate-to-high accuracy in irregular pulse detection, further improved by AI-assisted algorithms. Limitations included motion artifacts, false positives, adherence issues, clinician data burden, and limited evidence for stroke prevention.

CONCLUSION

Wearable ECG devices are reliable for clinical AF detection. PPG-based devices are best used for screening, with subsequent ECG confirmation according to international AF management guidelines.

Для цитирования: Bin Rashid Abdullah, Aslam Eman, Ashraf Isha, Mubeen Tehreem, Mubeen Amen, Zakriya Hamna, Amjad Maryam. Wearable devices for atrial fibrillation: diagnostic and screening roles of ECG and PPG-A systematic review.. Future cardiology. 2026. DOI: 10.1080/14796678.2026.2689050.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.