MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00586-024-08543-9

Медицинская библиотека · European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2024

Influence of implant density on mechanical complications in adult spinal deformity surgery.

Charles Yann Philippe, Severac François, Núñez-Pereira Susana, Haddad Sleiman, Vila Lluis, Pellisé Ferran, Obeid Ibrahim, Boissière Louis, Yilgor Caglar, Yucekul Altug, Alanay Ahmet, Kleinstück Frank, Loibl Markus, Gómez-Rice Alejandro, Raganato Riccardo, Perez-Grueso Francisco Javier Sánchez, Pizones Javier, European Spine Study Group (ESSG)

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The purpose was to analyze how rod characteristics, screw density and cages influence the incidence of mechanical complications compared to patient-related factors and alignment in adult spinal deformity instrumented T9-T11 to pelvis.

METHODS

Register data of 302 patients was analyzed. Relative lumbar lordosis (RLL) and relative sagittal alignment (RSA) was measured. Surgical data included rod characteristics, pedicle screw density and interbody cages. Univariate and multivariate logistic regression models were used.

RESULTS

Pseudarthrosis occurred in 24.1%. On univariate analysis Odds Ratio (OR) was 0.74 for ≥ 3 cages (p = 0.452), 0.48 for 4 rods (p = 0.008), 4.30 for high screw density (p = 0.001). Patient-related factors were non-significant. Multivariate OR was 0.59 for 4 rods (p = 0.084) and 4.67 for high screw density (p = 0.005). PJK/PJF occurred in 19.2%. Age > 60 had an OR 2.83 (p = 0.023), postoperative RSA malaligned OR 2.84 (p = 0.030), severely malaligned OR 6.54 (p < 0.001). Implant characteristics were non-significant. Multivariate OR was 1.26 for age > 60 (p = 0.657), 2.32 for malaligned RSA (p = 0.097), 5.69 for severely malaligned RSA (p = 0.001). Screw loosening occurred in 8.9%. Univariate OR was 0.95 for ≥ 3 cages (p = 0.920), 1.64 for 4 rods (p = 0.235), 0.25 for high screw density 1.5-2 (p = 0.011). Patient-related factors were non-significant. Multivariate OR for high screw density was 0.23 (p = 0.022).

CONCLUSION

Four rods decrease the pseudarthrosis risk. Cages have a secondary role. High screw density doesn't prevent from pseudarthrosis. Postoperative malalignment is the main PJK/PJF risk factor. Age plays a secondary role. Implant characteristics have a minor influence. High screw density constructs have a lower risk for screw loosening.

LEVEL OF EVIDENCE: 3-Retrospective register study.

Для цитирования: Charles Yann Philippe, Severac François, Núñez-Pereira Susana, Haddad Sleiman, Vila Lluis, Pellisé Ferran, Obeid Ibrahim, Boissière Louis, Yilgor Caglar, Yucekul Altug, Alanay Ahmet, Kleinstück Frank, Loibl Markus, Gómez-Rice Alejandro, Raganato Riccardo, Perez-Grueso Francisco Javier Sánchez, Pizones Javier, European Spine Study Group (ESSG). Influence of implant density on mechanical complications in adult spinal deformity surgery.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2024. DOI: 10.1007/s00586-024-08543-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.