BACKGROUND

The zero-profile implant system (Zero-P) and conventional plates have been widely used in anterior cervical discectomy and fusion (ACDF) to treat cervical spondylosis. The purpose of this study was to compare the effects of the application of Zero-P and new conventional plates (ZEVO, Skyline) in ACDF on the sagittal imaging parameters of cervical spondylosis patients and to analyze their clinical efficacy.

METHODS

We conducted a retrospective study on 119 cervical spondylosis patients from January 2018 to December 2021, comparing outcomes between those receiving the Zero-P device (n = 63) and those receiving a novel conventional plate (n = 56, including 46 ZEVO and 10 Skyline plates) through ACDF. Cervical sagittal alignment was assessed pre- and postoperatively via lateral radiographs. The Japanese Orthopedic Association (JOA), Neck Disability Index (NDI), and visual analog scale (VAS) scores were recorded at baseline, after surgery, and at the 2-year follow-up to evaluate patient recovery and intervention success.

RESULTS

There were significant differences in the postoperative C0-C2 Cobb angle and postoperative sagittal segmental angle (SSA) between patients in the novel conventional plate group and those in the Zero-P group (P < 0.05). Postoperatively, there were significant changes in the C2‒C7 Cobb angle, C0‒C2 Cobb angle, SSA, and average surgical disc height (ASDH) compared to the preoperative values in both patient groups (P < 0.05). Dysphagia in the immediate postoperative period was lower in the Zero-P group than in the new conventional plate group (0% in the Zero-P group, 7.14% in the novel conventional plate group, P = 0.046), and the symptoms disappeared within 2 years in both groups. There was no statistically significant difference between the two groups in terms of complications of adjacent spondylolisthesis (ASD) at 2 years postoperatively (3.17% in the Zero-P group, 8.93% in the novel conventional plate group; P = 0.252). According to the subgroup analysis, there were significant differences in the postoperative C2‒C7 Cobb angle, C0‒C2 Cobb angle, T1 slope, and ASDH between the ZEVO group and the Skyline group (P < 0.05). Compared with the preoperative scores, the JOA, NDI, and VAS scores of all groups significantly improved at the 2-year follow-up (P < 0.01). According to the subgroup analysis, the immediate postoperative NDI and VAS scores of the ZEVO group were significantly better than those of the Skyline group (P < 0.05).

CONCLUSION

In ACDF, both novel conventional plates and Zero-P can improve sagittal parameters and related scale scores. Compared to the Zero-P plate, the novel conventional plate has a greater advantage in correcting the curvature of the surgical segment, but the Zero-P plate is less likely to produce postoperative dysphagia.

Для цитирования: Gong Yan, Zhuo Hang, Zhou Zelin, Cheng Zhaojun, Gan Yanchi, He Jiahui, Song Zefeng, Liu Hao, Liu Yu, Liang De, Jiang Xiaobing, Ren Hui. Zero-profile implant system versus novel plate systems after ACDF for comparison of sagittal balance parameters and clinical efficacy analysis.. Journal of orthopaedic surgery and research. 2024. DOI: 10.1186/s13018-024-04857-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.