m+Medelevator.RU
← Поиск публикаций
Journal of ISAKOS : joint disorders & orthopaedic sports medicine · 2026

Shelf acetabuloplasty restores native rotational motion in a cadaveric acetabular dysplasia model.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Nishimura Haruki, Yamaura Kohei, Brown Justin, Garcia Alex, Drumm Amelia, Brady Alex, Stetzelberger Vera, Kuhns Ben, Murata Yoichi, Uchida Soshi, Philippon Marc

Аннотация

INTRODUCTION/OBJECTIVES: Developmental dysplasia of the hip is associated with inferior clinical outcomes when treating concomitant intra-articular pathologies. Shelf acetabuloplasty has been proposed as a less invasive alternative to periacetabular osteotomy for developmental dysplasia of the hip; however, there is a lack of biomechanical studies regarding its efficacy. We hypothesized that a cadaveric dysplasia model would cause increased range of motion and lateral femoral head translation compared to native, and that shelf acetabuloplasty would restore native biomechanics.

METHODS: Ten cadaveric hips were dissected down to the capsule and mounted to a six-degree-of-freedom robotic arm. Each specimen was tested sequentially in 4 states: 1) Native, 2) Capsular repair, 3) Acetabular dysplasia model created by acetabular rim resection to achieve a lateral center-edge angle (LCEA) of 15-20° under fluoroscopic guidance, and 4) Shelf acetabuloplasty restoring LCEA of 35-40° utilizing a bone graft harvested from the iliac crest. Robotic testing included: 1) 5- Newton Meter (Nm) abduction, 2) 5-Nm internal rotation (IR) at 75° flexion, 3) 5-Nm flexion, and 4) 88-N lateral drawer. Range of motion under standardized torque was used as a surrogate measure of rotational stability. The effect of specimen state was determined using analysis of variance, and post hoc pairwise comparisons were made using Tukey's method.

RESULTS: Capsular repair did not statistically significantly differ from the native state. Compared to native, the acetabular dysplasia model showed increased abduction (+2.3°, p = 0.004) and IR at 75° flexion (+0.9°, p = 0.017) without statistically significant changes in flexion or lateral translation. Shelf acetabuloplasty restored native abduction and IR at 75° flexion but reduced hip flexion (-1.7°, p = 0.003).

CONCLUSION: This study demonstrated that acetabular rim resection increased rotational motion under applied torque, while shelf acetabuloplasty restored rotational motion to native levels. However, shelf acetabuloplasty resulted in a statistically significant reduction in hip flexion (-1.7°, p = 0.003), suggesting potential over-constraint depending on graft positioning.

LEVEL OF EVIDENCE: Not Applicable, Controlled Laboratory Study.

Предметные рубрики MeSH