MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/rheumatology/keaf323

Медицинская библиотека · Rheumatology (Oxford, England) · 2025

Automated detection of spinal bone marrow oedema in axial spondyloarthritis: training and validation using two large phase 3 trial datasets.

Jamaludin Amir, Windsor Rhydian, Ather Sarim, Kadir Timor, Zisserman Andrew, Braun Juergen, Gensler Lianne S, Østergaard Mikkel, Poddubnyy Denis, Coroller Thibaud, Porter Brian, Ligozio Gregory, Readie Aimee, Machado Pedro M

Клиническое исследование III фазыСтатьяРандомизированное исследованиеВалидационное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the performance of machine learning (ML) models for the automated scoring of spinal MRI bone marrow oedema (BMO) in patients with axial spondyloarthritis (axSpA) and compare them with expert scoring.

METHODS

ML algorithms using SpineNet software were trained and validated on 3483 spinal MRIs from 686 axSpA patients across two clinical trial datasets. The scoring pipeline involved (i) detection and labelling of vertebral bodies and (ii) classification of vertebral units for the presence or absence of BMO. Two models were tested: Model 1, without manual segmentation, and Model 2, incorporating an intermediate manual segmentation step. Model outputs were compared with those of human experts using kappa statistics, balanced accuracy, sensitivity, specificity and AUC.

RESULTS

Both models performed comparably to expert readers, regarding presence vs absence of BMO. Model 1 outperformed Model 2, with an AUC of 0.94 (vs 0.88), accuracy of 75.8% (vs 70.5%) and kappa of 0.50 (vs 0.31) using absolute reader consensus scoring as the external reference; this performance was similar to the expert inter-reader accuracy of 76.8% and kappa of 0.47 in a radiographic axSpA dataset. In a non-radiographic axSpA dataset, Model 1 achieved an AUC of 0.97 (vs 0.91 for Model 2), accuracy of 74.6% (vs 70%) and kappa of 0.52 (vs 0.27), comparable to the expert inter-reader accuracy of 74.2% and kappa of 0.46.

CONCLUSION

ML software shows potential for automated MRI BMO assessment in axSpA, offering benefits such as improved consistency, reduced labour costs and minimized inter- and intra-reader variability.

TRIAL REGISTRATION: Clinicaltrials.gov, http://clinicaltrials.gov, MEASURE 1 study (NCT01358175); PREVENT study (NCT02696031).

Для цитирования: Jamaludin Amir, Windsor Rhydian, Ather Sarim, Kadir Timor, Zisserman Andrew, Braun Juergen, Gensler Lianne S, Østergaard Mikkel, Poddubnyy Denis, Coroller Thibaud, Porter Brian, Ligozio Gregory, Readie Aimee, Machado Pedro M. Automated detection of spinal bone marrow oedema in axial spondyloarthritis: training and validation using two large phase 3 trial datasets.. Rheumatology (Oxford, England). 2025. DOI: 10.1093/rheumatology/keaf323.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.