Wearable bio-adhesive metal detector array (BioMDA) for spinal implants.

Li Jian, Jia Shengxin, Li Dengfeng, Chow Lung, Zhang Qiang, Yang Yiyuan, Bai Xiao, Qu Qingao, Gao Yuyu, Li Zhiyuan, Li Zongze, Shi Rui, Zhang Binbin, Huang Ya, Pan Xinyu, Hu Yue, Gao Zhan, Zhou Jingkun, Park WooYoung, Huang Xingcan, Chu Hongwei, Chen Zhenlin, Li Hu, Wu Pengcheng, Zhao Guangyao, Yao Kuanming, Hadzipasic Muhamed, Bernstock Joshua D, Shankar Ganesh M, Nan Kewang, Yu Xinge, Traverso Giovanni

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Dynamic tracking of spinal instrumentation could facilitate real-time evaluation of hardware integrity and in so doing alert patients/clinicians of potential failure(s). Critically, no method yet exists to continually monitor the integrity of spinal hardware and by proxy the process of spinal arthrodesis; as such hardware failures are often not appreciated until clinical symptoms manifest. Accordingly, herein, we report on the development and engineering of a bio-adhesive metal detector array (BioMDA), a potential wearable solution for real-time, non-invasive positional analyses of osseous implants within the spine. The electromagnetic coupling mechanism and intimate interfacial adhesion enable the precise sensing of the metallic implants position without the use of radiation. The customized decoupling models developed facilitate the precise determination of the horizontal and vertical positions of the implants with incredible levels of accuracy (e.g., <0.5 mm). These data support the potential use of BioMDA in real-time/dynamic postoperative monitoring of spinal implants.

Для цитирования: Li Jian, Jia Shengxin, Li Dengfeng, Chow Lung, Zhang Qiang, Yang Yiyuan, Bai Xiao, Qu Qingao, Gao Yuyu, Li Zhiyuan, Li Zongze, Shi Rui, Zhang Binbin, Huang Ya, Pan Xinyu, Hu Yue, Gao Zhan, Zhou Jingkun, Park WooYoung, Huang Xingcan, Chu Hongwei, Chen Zhenlin, Li Hu, Wu Pengcheng, Zhao Guangyao, Yao Kuanming, Hadzipasic Muhamed, Bernstock Joshua D, Shankar Ganesh M, Nan Kewang, Yu Xinge, Traverso Giovanni. Wearable bio-adhesive metal detector array (BioMDA) for spinal implants.. Nature communications. 2024. DOI: 10.1038/s41467-024-51987-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.