MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00701-019-03944-y

Медицинская библиотека · Acta neurochirurgica · 2019

A cadaveric study using the ultra-minimally invasive thread transection technique to decompress the superficial peroneal nerve in the lower leg.

Guo Danzhu, Guo Danqing, Harrison Richard, McCool Logan, Wang Hao, Tonkin Brionn, Kliot Michel

СтатьяПеревод в очереди

Аннотация

BACKGROUND

After successful applications of the ultra-minimally invasive thread transecting technique (Guo Technique) for both thread carpal tunnel release and thread trigger finger release, we hypothesized that this technique could be used for superficial peroneal nerve release in the lower leg by selective crural fasciectomy. This study is aimed at testing the operative feasibility of performing the thread superficial peroneal nerve release (TSPNR) procedure in cadavers.

METHODS

The TSPNR procedure was performed on 15 fresh frozen cadaveric lower-extremity specimens under ultrasound guidance. All cadaveric specimens were dissected and visually assessed immediately after the procedures.

RESULTS

All 15 legs demonstrated a complete transection of the crural fasciae along the course of the superficial peroneal nerve (SPN) including where it penetrated and traversed the crural fascia. There was no evidence of any iatrogenic damage to the neurovascular bundle or adjacent tendons. The average operating time was less than 20 min.

CONCLUSION

This cadaveric study demonstrated that the technique of TSPNR was accurate, reliable, and feasible while causing no injury to adjacent neurovascular structures and avoiding having to make a skin incision. Further studies are warranted to verify the results of this study before implementing this new technique in the clinical setting.

Для цитирования: Guo Danzhu, Guo Danqing, Harrison Richard, McCool Logan, Wang Hao, Tonkin Brionn, Kliot Michel. A cadaveric study using the ultra-minimally invasive thread transection technique to decompress the superficial peroneal nerve in the lower leg.. Acta neurochirurgica. 2019. DOI: 10.1007/s00701-019-03944-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.