MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/bpo.0000000000002739

Медицинская библиотека · Journal of pediatric orthopedics · 2024

Preliminary Study of Motion Preservation Following Posterior Dynamic Distraction Device in Adolescent Idiopathic Scoliosis Patients.

Todderud Julia E, Milbrandt Todd A, Floyd Edward, Haft Geoffrey, El-Hawary Ron, Albert Michael, Larson A Noelle

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Motion-sparing scoliosis surgeries such as the posterior dynamic distraction device (PDDD) are slowly increasing in use. However, there is limited clinical data documenting postoperative motion across the PDDD construct. With this cohort study, we aim to measure sagittal and coronal motion following PDDD. We hypothesize coronal and sagittal spinal motion will be partially preserved across the construct.

METHODS

Retrospective review of prospectively collected data. Preoperative and minimum 1-year postoperative coronal range of motion across the instrumented levels was compared. Available flexion/extension radiographs were evaluated postoperatively to assess sagittal arc of motion. Radiographs from latest follow-up were used.

RESULTS

At a mean of 1.9 years (1 to 5 y), flexibility radiographs were available on 29 patients treated with PDDD (17 thoracic, 12 lumbar). Mean age at surgery was 16 years (12 to 25). Postoperative coronal arc of motion in PDDD patients was 11 degrees (3 to 19 degrees) in the thoracic spine and 10 degrees (0 to 28 degrees) in the lumbar spine. Compared with preoperative motion, the thoracic arc of motion was maintained by 33% (35 to 11 degrees) and lumbar motion was maintained by 30% (34 to 10 degrees). Flexion-extension radiographs were available on 7 patients. Sagittal arc for the upper instrumented vertebral end plate to the lower instrumented vertebral endplate of the cohort was 10 degrees in the thoracic spine (6 to 18) and 14 degrees in the lumbar spine (5 to 21). Sagittal measurements for the changes in the arc of the upper and lower screws on the construct were 4 degrees in the thoracic group (2 to 8) and 9 degrees in the lumbar group (2 to 17). By latest follow-up 11 patients (38%) underwent reoperation, with most cases due to implant breakage (N=4, 14%), extender misalignment (N=2, 7%), and screw misplacement (N=2, 7%).

CONCLUSION

At mean 1.9 years postoperatively, PDDD preserves measurable spinal motion over the construct both in the coronal and the sagittal plane without evidence for autofusion. Coronal arc of motion averages 10 to 12 degrees and sagittal arc of motion ranged from 4 to 14 degrees, although this varies by patient. This study confirms that PDDD for pediatric scoliosis preserves a measurable degree of postoperative flexibility both in the sagittal and coronal planes.

LEVEL OF EVIDENCE: Level II-therapeutic study.

Для цитирования: Todderud Julia E, Milbrandt Todd A, Floyd Edward, Haft Geoffrey, El-Hawary Ron, Albert Michael, Larson A Noelle. Preliminary Study of Motion Preservation Following Posterior Dynamic Distraction Device in Adolescent Idiopathic Scoliosis Patients.. Journal of pediatric orthopedics. 2024. DOI: 10.1097/bpo.0000000000002739.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.