MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.otsr.2024.103901

Медицинская библиотека · Orthopaedics & traumatology, surgery & research : OTSR · 2024

Dedicated locking plate reduces non-union risk in open ankle fusion in obese patients.

Nicot Claire, David Guillaume, Marc Clément, Hubert Laurent, Rony Louis

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

INTRODUCTION

Obesity is a growing public health concern. In ankle osteoarthritis, non-conservative treatment in advanced stages consists in ankle fusion, or else total ankle replacement, for which obesity is a relative contraindication. One of main complications of ankle fusion is non-union. Devascularization, obesity and fixation material are all factors involved in postoperative non-union, and have to be taken into account in surgical strategy for reliable results. The objective of this study was to compare the rate of ankle non-union in obese patients using quadruple screwing or a dedicated locking plate. The hypothesis was that the locking plate limits the risk of non-union in this population.

METHODS

All patients were obese (BMI>30kg/m2) and presented ankle osteoarthritis with>10° intra-articular deformity. The approach and joint preparation were performed via an anteromedial approach. Group S was composed of 32 patients, operated on by quadruple screwing; group P comprised 10 patients operated on using a dedicated locking plate. The main endpoint was a significant difference in the rate of non-union between the 2 groups. The secondary endpoint was improvement in pre- and 6-month postoperative AOFAS score.

RESULTS

Group S presented 31% non-union (10/32) and group P 0% (0/10) (p<0.05). Postoperative AOFAS score was significantly higher in group P: 67.8±10.4 [range, 40-92] vs. 83.1±8.0 [range, 64-92] (p<0.05).

CONCLUSION

The dedicated anterior locking plate is a technique of choice for ankle fusion in obese patients with intra-articular deformity>10°, to limit the risk of non-union.

LEVEL OF EVIDENCE: IV; retrospective study.

Для цитирования: Nicot Claire, David Guillaume, Marc Clément, Hubert Laurent, Rony Louis. Dedicated locking plate reduces non-union risk in open ankle fusion in obese patients.. Orthopaedics & traumatology, surgery & research : OTSR. 2024. DOI: 10.1016/j.otsr.2024.103901.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.