Clinical neurology and neurosurgery · 2015
The positive correlation between upper adjacent vertebral fracture and the kyphosis angle of injured vertebral body after percutaneous kyphoplasty: An in vitro study.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lu Jiye, Jiang Guoqiang, Lu Bin, Shi Chaolu, Luo Kefeng, Yue Bing
Аннотация
OBJECTIVE: To investigate the correlation between the kyphosis angle of injured vertebral body and the risk of upper adjacent vertebral fracture after percutaneous kyphoplasty (PKP) using an osteoporotic vertebral compressed fracture model.
MATERIALS AND METHODS: 24 functional spinal units (FSUs, T9 to L4) were selected from 6 elderly formalin preserved vertebral specimens to build the vertebral compressed fracture model. According to the kyphosis angle between the upper plate of upper vertebral body and the horizontal plane, group A (0°) and group B (20°) were defined, with each group comprised with 12 FSUs. The stiffness and fracture load were measured in both groups.
RESULTS: After PKP, the stiffness was (571.513 ± 83.373)N/mm and the fracture load was (1751.659 ± 112.291)N in group A, with both significantly higher than those of group B (stiffness, (307.706 ± 46.723)N/mm; fracture load, (1128.011 ± 125.417)N).
CONCLUSIONS: To reduce the risk of upper adjacent vertebral fracture, it is better to restore the height of injured vertebral body and decrease the angle of kyphosis to increase the capability of upper adjacent vertebral body against fracture.
MATERIALS AND METHODS: 24 functional spinal units (FSUs, T9 to L4) were selected from 6 elderly formalin preserved vertebral specimens to build the vertebral compressed fracture model. According to the kyphosis angle between the upper plate of upper vertebral body and the horizontal plane, group A (0°) and group B (20°) were defined, with each group comprised with 12 FSUs. The stiffness and fracture load were measured in both groups.
RESULTS: After PKP, the stiffness was (571.513 ± 83.373)N/mm and the fracture load was (1751.659 ± 112.291)N in group A, with both significantly higher than those of group B (stiffness, (307.706 ± 46.723)N/mm; fracture load, (1128.011 ± 125.417)N).
CONCLUSIONS: To reduce the risk of upper adjacent vertebral fracture, it is better to restore the height of injured vertebral body and decrease the angle of kyphosis to increase the capability of upper adjacent vertebral body against fracture.