MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/230949900701500319

Медицинская библиотека · Journal of orthopaedic surgery (Hong Kong) · 2007

Management outcome and the role of manipulation in slipped capital femoral epiphysis.

Lim Y J, Lam K S, Lim K Bl, Mahadev A, Lee E H

СтатьяПеревод в очереди

Аннотация

PURPOSE: To examine and compare treatment outcomes for slipped capital femoral epiphysis (SCFE).

METHODS

24 patients with acute or acute-on-chronic SCFE underwent preoperative traction, 13 of them followed by in situ screw fixation (group A), and the remaining 11, manipulation with screw fixation (group B). Their treatment outcomes (according to the Aadalen criteria) and complications were compared.

RESULTS

There were 2 treatment failures and one poor outcome in patients with acute SCFE (2 had avascular necrosis and one had slight pain with mild limitation of hip movement). The risk of developing avascular necrosis was significantly higher in patients with acute rather than acute-on-chronic or chronic slips. No significant differences were evident between groups A and B with regard to age, sex, ethnicity, outcomes, and preoperative and postoperative changes in the Southwick headshaft angle.

CONCLUSION

Patients with acute or acute-on-chronic SCFE can be safely managed with straight-leg traction for up to 6 days, followed by in situ screw fixation without manipulation. Manipulation is not recommended in such slips, due to a higher avascular necrosis risk.

Для цитирования: Lim Y J, Lam K S, Lim K Bl, Mahadev A, Lee E H. Management outcome and the role of manipulation in slipped capital femoral epiphysis.. Journal of orthopaedic surgery (Hong Kong). 2007. DOI: 10.1177/230949900701500319.