Simultaneous biplanar fluoroscopy for the surgical treatment of slipped capital femoral epiphysis.
Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Westberry David E, Davids Jon R, Cross Andrew, Tanner Stephanie L, Blackhurst Dawn W
Аннотация
BACKGROUND: The current standard of care for treatment of slipped capital femoral epiphysis (SCFE) is in situ placement of a single, cannulated screw across the physis under direct fluoroscopic guidance. Previous studies have reported the theoretical advantages of shorter operative time and improved accuracy of screw placement when 2 fluoroscopy units are used simultaneously.
METHODS: A retrospective review was performed to compare the use of 1 versus 2 C-arms in the surgical stabilization of SCFE. Data analysis, including demographics, surgical setup times, operative times, and precision of screw placement was performed in 77 consecutive hips (69 patients).
RESULTS: No significant differences were found between the single and dual C-arm techniques with respect to operating room setup and surgery times. Center-center positioning of the screw was more precise when using the simultaneous dual C-arm technique. Surgical times were longer in obese children, irrespective of the number of C-arms used.
CONCLUSIONS: Efficient operating room setup time for the dual C-arm technique is possible. Precision of screw placement is improved when using simultaneous biplanar fluoroscopy for the in situ pinning of SCFE.
METHODS: A retrospective review was performed to compare the use of 1 versus 2 C-arms in the surgical stabilization of SCFE. Data analysis, including demographics, surgical setup times, operative times, and precision of screw placement was performed in 77 consecutive hips (69 patients).
RESULTS: No significant differences were found between the single and dual C-arm techniques with respect to operating room setup and surgery times. Center-center positioning of the screw was more precise when using the simultaneous dual C-arm technique. Surgical times were longer in obese children, irrespective of the number of C-arms used.
CONCLUSIONS: Efficient operating room setup time for the dual C-arm technique is possible. Precision of screw placement is improved when using simultaneous biplanar fluoroscopy for the in situ pinning of SCFE.