MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3233/xst-180480

Медицинская библиотека · Journal of X-ray science and technology · 2019

Using synovial volume measurement by MRI to evaluate the effect of 32P Radiation synovectomy on hemophilic arthropathy patients.

Dou Yincong, Li Meixia, Zhang Lu, Cheng Tianming, Lei Pingchong, Ge Yinghui

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the potential of synovial membrane volume measurement by MRI in monitoring the effect of radiation synovectomy on patients of Hemophilic Arthropathy (HA).

METHODS

We studied 63 diseased joints of 42 HA patients who received hospitalized services at the Hemophilia Diagnosis and Treatment Center of Henan Provincial People's Hospital from May 2011 to January 2015. Unenhanced and enhanced MR scanning of each diseased joint was performed simultaneously. The volumes of synovial membrane of 21 joints from 16 patients before and after being treated with 32P radiation synovectomy (PRS) were measured and compared using image post-processing software and workstation. Two sample matching t test was conducted to analyze the synovial membrane volumes of the same joint measured by unenhanced and enhanced MR, as well as change of MR enhancement ratio after treatments.

RESULTS

The synovial membrane volumes measured by unenhanced versus enhanced MR scanning showed no statistical significance. Significant reduction (t = 7.831, p < 0.001) of the synovial membrane volume after treatment (2479.45±46.48 mm3 versus 2983.30±42.87 mm3 before treatment) was observed. MR enhancement ratio of synovial membrane decreased after treatment (0.92±0.06 after vs 1.17±0.07 before treatment) with statistical significance.

CONCLUSION

The synovial membrane volume and MR enhancement ratio can be used to monitor patient response to PRS treatment.

Для цитирования: Dou Yincong, Li Meixia, Zhang Lu, Cheng Tianming, Lei Pingchong, Ge Yinghui. Using synovial volume measurement by MRI to evaluate the effect of 32P Radiation synovectomy on hemophilic arthropathy patients.. Journal of X-ray science and technology. 2019. DOI: 10.3233/xst-180480.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.