ASTM F1717 standard for the preclinical evaluation of posterior spinal fixators: can we improve it?

La Barbera Luigi, Galbusera Fabio, Villa Tomaso, Costa Francesco, Wilke Hans-Joachim

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод в очереди

Аннотация

Preclinical evaluation of spinal implants is a necessary step to ensure their reliability and safety before implantation. The American Society for Testing and Materials reapproved F1717 standard for the assessment of mechanical properties of posterior spinal fixators, which simulates a vertebrectomy model and recommends mimicking vertebral bodies using polyethylene blocks. This set-up should represent the clinical use, but available data in the literature are few. Anatomical parameters depending on the spinal level were compared to published data or measurements on biplanar stereoradiography on 13 patients. Other mechanical variables, describing implant design were considered, and all parameters were investigated using a numerical parametric finite element model. Stress values were calculated by considering either the combination of the average values for each parameter or their worst-case combination depending on the spinal level. The standard set-up represents quite well the anatomy of an instrumented average thoracolumbar segment. The stress on the pedicular screw is significantly influenced by the lever arm of the applied load, the unsupported screw length, the position of the centre of rotation of the functional spine unit and the pedicular inclination with respect to the sagittal plane. The worst-case combination of parameters demonstrates that devices implanted below T5 could potentially undergo higher stresses than those described in the standard suggestions (maximum increase of 22.2% at L1). We propose to revise F1717 in order to describe the anatomical worst case condition we found at L1 level: this will guarantee higher safety of the implant for a wider population of patients.

Для цитирования: La Barbera Luigi, Galbusera Fabio, Villa Tomaso, Costa Francesco, Wilke Hans-Joachim. ASTM F1717 standard for the preclinical evaluation of posterior spinal fixators: can we improve it?. Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine. 2014. DOI: 10.1177/0954411914554244.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.