MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12891-024-07213-7

Медицинская библиотека · BMC musculoskeletal disorders · 2024

Myth or fact: 3D-printed off-the-shelf prosthesis is superior to titanium mesh cage in anterior cervical corpectomy and fusion?

He Haoyu, Fan Lei, Lü Guohua, Li Xinyi, Li Yunchao, Zhang Ou, Chen Zejun, Yuan Hui, Pan Changyu, Wang Xiaoxiao, Kuang Lei

СтатьяПеревод в очереди

Аннотация

BACKGROUND

To find out if three-dimensional printing (3DP) off-the-shelf (OTS) prosthesis is superior to titanium mesh cages in anterior cervical corpectomy and fusion (ACCF) when treating single-segment degenerative cervical spondylotic myelopathy (DCSM).

METHODS

DCSM patients underwent ACCF from January 2016 to January 2019 in a single center were included. Patients were divided into the 3DP group (28) and the TMC group (23). The hospital stays, operation time, intraoperative blood loss, and the cost of hospitalization were compared. The Japanese Orthopedic Association (JOA) scores and Neck Disability Index (NDI) were recorded pre-operatively, 1 day, 3, 6, 12, and 24 months post-operatively. Radiological data was measured to evaluate fusion, subsidence, and cervical lordosis. Patients were sent with SF-36 to assess their health-related quality of life (HRQoL).

RESULTS

The differences in operative time, intraoperative blood loss, and hospital stay were not statistically significant between groups (p > 0.05). Postoperative dysphagia occurred in 2 cases in the 3DP group and 3 cases in the TMC group, which all relieved one week later. The difference in improvement of JOA and NDI between the two groups was not statistically significant (p > 0.05). No hardware failure was found and bony fusion was achieved in all cases except one in the 3DP group. The difference in cervical lordosis (CL), fused segmental angle (FSA), mean vertebral height (MVH), and subsidence rates between groups at each follow-up time point was not statistically significant and the results of the SF-36 were similar (p > 0.05). The total cost was higher in the 3DP group with its higher graft cost (p < 0.05).

CONCLUSION

In treating single-segment DCSM with ACCF, both 3DP OTS prosthesis and TMC achieved satisfactory outcomes. However, the more costly 3DP OTS prosthesis was not able to reduce subsidence as it claimed.

Для цитирования: He Haoyu, Fan Lei, Lü Guohua, Li Xinyi, Li Yunchao, Zhang Ou, Chen Zejun, Yuan Hui, Pan Changyu, Wang Xiaoxiao, Kuang Lei. Myth or fact: 3D-printed off-the-shelf prosthesis is superior to titanium mesh cage in anterior cervical corpectomy and fusion?. BMC musculoskeletal disorders. 2024. DOI: 10.1186/s12891-024-07213-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.