MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11914-026-00959-0

Медицинская библиотека · Current osteoporosis reports · 2026

Health-related Quality of Life After Vertebral Augmentation for Osteoporotic Vertebral Compression Fractures.

Wei Si, Cai Zhenjin, Zheng Hao, Zhang Hongjie, Quan Xiaoli, Luo Yaoyue, Wang Guangwei

СтатьяОбзорПеревод в очереди

Аннотация

PURPOSE OF REVIEW: Health-related quality of life (HRQOL) in patients with osteoporotic vertebral compression fractures (OVCFs) varies significantly. This review summarizes the mechanisms of HRQOL impairment and evaluates the clinical evidence for vertebral augmentation (VA) procedures, specifically percutaneous vertebroplasty (PV), balloon kyphoplasty (BKP), and third-generation percutaneous vertebral augmentation systems (TVA). Additionally, we identify key factors influencing postoperative HRQOL recovery. RECENT FINDINGS: OVCFs severely impair physical function and psychosocial well-being, increasing mortality risk by approximately 22%. While VA effectively alleviates pain and restores vertebral height, current evidence is largely limited to paired comparisons, and 8% to 40% of patients report persistent or recurrent postoperative pain. Crucially, few studies systematically compare HRQOL across the three primary VA techniques. Furthermore, significant methodological heterogeneity in surgical protocols and assessment tools continues to hinder the comparability of long-term functional outcomes. This review comprehensively examines the disparities in HRQOL recovery following VA for OVCFs and identifies critical research gaps. Further studies are warranted to elucidate the mechanisms underlying these variations, enabling the development of targeted clinical interventions.

Для цитирования: Wei Si, Cai Zhenjin, Zheng Hao, Zhang Hongjie, Quan Xiaoli, Luo Yaoyue, Wang Guangwei. Health-related Quality of Life After Vertebral Augmentation for Osteoporotic Vertebral Compression Fractures.. Current osteoporosis reports. 2026. DOI: 10.1007/s11914-026-00959-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.