MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-021-03961-6

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2021

Reliable ligamentous stability and high return-to-sport rates after arthroscopic reduction and internal fixation of tibial eminence fractures.

Lutz Patricia M, Geyer Stephanie, Winkler Philipp W, Irger Markus, Berthold Daniel P, Feucht Matthias J, Imhoff Andreas B, Forkel Philipp

СтатьяПеревод в очереди

Аннотация

PURPOSE: To investigate functional and clinical outcomes, and physical activity after arthroscopic suture fixation of tibial eminence fractures with regard to postoperative stability, range of motion (ROM), complications, and return to sports.

METHODS

Patients undergoing arthroscopic reduction and internal fixation (ARIF) of tibial eminence fractures using a suture fixation technique were included. Outcome was evaluated retrospectively after a minimum follow-up of 24 months using KT-1000 arthrometer measurements, clinical examination, outcome scores (Lysholm score, Tegner Activity Scale), and a questionnaire about sport activities.

RESULTS

A total of 23 patients (44% male, 57% female) with a mean age of 25 ± 15 years were included. Mean follow-up was 57 ± 25 months. KT-1000 arthrometer measurements of anterior tibial translation revealed a mean side-to-side difference of 0.9 ± 1.0 mm. Clinical examination showed 100% normal or nearly normal anterior translation of the tibia. Two patients (9%) received an ACL reconstruction due to traumatic ACL re-instability and were, therefore, considered as failures. An extension deficit concerning hyperextension occurred in 29% of patients postoperatively. Further postoperative complications occurred in 14% of patients and included postoperative stiffness with ROM limitations and secondary dislocation of a fragment. Mean postoperative Lysholm score was 89 ± 14. Comparing pre- and postoperative values, no significant change of the Tegner Activity Scale was observed. All patients (failures excluded) returned to high impact sports activities after ARIF.

CONCLUSION

Excellent reliable ligamentous stability and high rates of return to high impact sports can be expected after ARIF using a suture fixation technique for type II-IV tibial eminence fractures. Complications, such as limitations in ROM, commonly occur in up to 30% after ARIF. Therefore, regular follow-up examinations remain important in this usually young patient cohort.

LEVEL OF EVIDENCE: Level IV.

Для цитирования: Lutz Patricia M, Geyer Stephanie, Winkler Philipp W, Irger Markus, Berthold Daniel P, Feucht Matthias J, Imhoff Andreas B, Forkel Philipp. Reliable ligamentous stability and high return-to-sport rates after arthroscopic reduction and internal fixation of tibial eminence fractures.. Archives of orthopaedic and trauma surgery. 2021. DOI: 10.1007/s00402-021-03961-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.