DOI 10.1016/j.spinee.2023.10.020
Prospective, multicenter clinical trial comparing the M6-C compressible cervical disc with anterior cervical discectomy and fusion for the treatment of single-level degenerative cervical radiculopathy: 5-year results of an FDA investigational device exemption study.
Аннотация
BACKGROUND CONTEXT: Various total disc replacement (TDR) designs have been compared to anterior cervical discectomy and fusion (ACDF) with favorable short and long-term outcomes in FDA-approved investigational device exemption (IDE) trials. The unique design of M6-C, with a compressible viscoelastic nuclear core and an annular structure, has previously demonstrated favorable clinical outcomes through 24 months.
PURPOSE: To evaluate the long-term safety and effectiveness of the M6-C compressible artificial cervical disc and compare to ACDF at 5 years.
STUDY
DESIGN
Prospective, multicenter, concurrently and historically controlled, FDA-approved IDE clinical trial.
PATIENT SAMPLE: Subjects with one-level symptomatic degenerative cervical radiculopathy were enrolled and received M6-C (n=160) or ACDF (n=189) treatment as part of the IDE study. Safety outcomes were evaluated at 5 years for all subjects. The primary effectiveness endpoint was available at 5 years for 113 M6-C subjects and 106 ACDF controls.
OUTCOME MEASURES: The primary endpoint of this analysis was composite clinical success (CCS) at 60 months. Secondary endpoints were function and pain (neck disability index, VAS), physical quality of life (SF-36, SF-12), safety, neurologic, and radiographic assessments.
METHODS
Propensity score subclassification was used to control for selection bias and match baseline covariates of the control group to the M6-C subjects. Sixty-month CCS rates were estimated for each treatment group using a generalized linear model controlling for propensity score.
RESULTS
At 5 years postoperatively, the M6-C treatment resulted in 82.3% CCS while the ACDF group showed 67.0% CCS (superiority p=.013). Secondary endpoints indicated that significantly more M6-C subjects achieved VAS neck and arm pain improvements and showed maintained or improved physical functioning on quality-of-life measures compared to baseline assessments. The M6-C group-maintained flexion-extension motion, with significantly greater increases from baseline disc height and disc angle than observed in the control group. The rates of M6-C subsequent surgical interventions (SSI; 3.1%) and definitely device- or procedure-related serious adverse events (SAE failure; 3.1%) were similar to ACDF rates (SSI=5.3%, SAE failure=4.8%; p>.05 for both).
CONCLUSIONS
Subjects treated with the M6-C artificial disc demonstrated superior 5-year achievement of clinical success when compared to ACDF controls. In addition, significantly more subjects in the M6-C group showed improved pain and physical functioning scores than observed in ACDF subjects, with no difference in reoperation rates or safety outcomes.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.