MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.wneu.2023.10.118

Медицинская библиотека · World neurosurgery · 2023

A Lateral Expandable Cage with Independently Adjustable Anterior and Posterior Heights Can Improve the Pressure Distribution at the Cage-Endplate Interface: A Biomechanics Study.

Kusins Jonathan, Uyekawa Scott, Singh Gurpreet, Peng Yun, McQuarrie Chase, Holman Paul, Cheng Ivan, Jekir Michael

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To investigate how the expansion trajectory of a lateral expandable cage affects pressure distribution at the cage-endplate interface under well-controlled biomechanical loading conditions.

METHODS

Three unique vertical height expansion trajectories used by clinically relevant lateral expandable cages were evaluated: craniocaudal, fixed-arc, and independently adjustable anterior and posterior height expansion. Two biomechanical loading scenarios were performed. The first scenario used custom bone foam test blocks to assess resultant pressure distribution at varying test block lordotic angles and expansion heights. The second scenario simulated expansion using synthetic spine units and compared the pressure distribution following expansion.

RESULTS

For an expandable cage with craniocaudal expansion, the pressure distribution at the cage-endplate interface was found to depend heavily on the lordotic angle of the test block (P < 0.001), but not expansion height (P = 0.634). The greatest maximum pressure occurred at higher test block lordotic angles. For an expandable cage with fixed-arc expansion, the pressure distribution shifted anteriorly throughout expansion. In the simulated expansion trials, an expandable cage with adjustable anterior and posterior height expansion was found to improve the pressure distribution at the cage-endplate interface, reducing the maximum pressure measurements by 22% and 14% in the craniocaudal and fixed-arc expansion, respectively.

CONCLUSIONS

Of the cage designs evaluated in this study, an expandable cage with independently adjustable anterior and posterior heights lowered the maximum pressure measured at the cage-endplate interface and alleviated the potential of cage edge loading, both of which are important considerations that are fundamental for a successful fusion procedure and the mitigation of implant subsidence risk.

Для цитирования: Kusins Jonathan, Uyekawa Scott, Singh Gurpreet, Peng Yun, McQuarrie Chase, Holman Paul, Cheng Ivan, Jekir Michael. A Lateral Expandable Cage with Independently Adjustable Anterior and Posterior Heights Can Improve the Pressure Distribution at the Cage-Endplate Interface: A Biomechanics Study.. World neurosurgery. 2023. DOI: 10.1016/j.wneu.2023.10.118.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.