MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3357/amhp.6485.2024

Медицинская библиотека · Aerospace medicine and human performance · 2024

Reliability of a Flight Helmet-Attached Force Gauge in Measuring Isometric Neck Muscle Strength.

Honkanen Tuomas, Mattila Ville, Kinnunen Otto, Janhunen Marjo, Sovelius Roope, Vaara Jani P, Kyröläinen Heikki

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Strong neck muscles may decrease the risk of flight-induced neck pain and possible disability among fast jet pilots. The purpose of this study was to examine the intra- and interrater reliability of a commercial force gauge attached to a pilot's helmet for measuring isometric force production of the neck muscles.

METHODS

A total of 41 subjects performed maximal isometric cervical flexion, extension, and lateral flexion in two measurement sessions for intrarater reliability, and 31 of these subjects participated in a third session for measuring interrater reliability. Delayed muscle soreness and neck pain were assessed using the Visual Analog Scale before and after each measurement session. The intraclass correlation coefficient (ICC) was used to compare values between the test and retest assessments.

RESULTS

The overall interrater reliability was good (ICC 0.79-0.90), whereas the intrarater reliability varied from moderate to good (ICC 0.58-0.84). In both intra- and interrater reliability, the flexion test had good (ICC 0.84-0.89) reliability, while the lateral flexion test results had moderate to good (ICC 0.73-0.90) reliability. The extension test had the lowest reliability in both intra- (ICC 0.58) and interrater (ICC 0.79) tests. The average visual analog scale score (from 1-100 scale) prior to the second measurement session was 16 ± 18 in delayed muscle soreness and 0 ± 0 in neck pain.

DISCUSSION: The present study demonstrated that the helmet-attached force gauge is a reliable, safe, and clinically applicable method to evaluate isometric neck strength in the flexion and lateral flexion directions. Honkanen T, Mattila V, Kinnunen O, Janhunen M, Sovelius R, Vaara JP, Kyröläinen H. Reliability of a flight helmet-attached force gauge in measuring isometric neck muscle strength. Aerosp Med Hum Perform. 2024; 95(10):788-793.

Для цитирования: Honkanen Tuomas, Mattila Ville, Kinnunen Otto, Janhunen Marjo, Sovelius Roope, Vaara Jani P, Kyröläinen Heikki. Reliability of a Flight Helmet-Attached Force Gauge in Measuring Isometric Neck Muscle Strength.. Aerospace medicine and human performance. 2024. DOI: 10.3357/amhp.6485.2024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.