MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/bpo.0000000000002018

Медицинская библиотека · Journal of pediatric orthopedics · 2022

Effect of the Number, Size, and Location of Cannulated Screws on the Incidence of Avascular Necrosis of the Femoral Head in Pediatric Femoral Neck Fractures: A Review of 153 Cases.

Wang Wentao, Li Yiqiang, Xiong Zhu, Guo Yueming, Li Ming, Mei Haibo, Shao Jingfan, Li Jin, Canavese Federico, Chen Shunyou

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The correlation between the number, size, and location of cannulated screws and the incidence of avascular necrosis (AVN) in children with femoral neck fractures treated surgically is uncertain.

METHODS

We retrospectively reviewed 153 children (mean age: 10.6±3.7 y) with femoral neck fractures treated by internal fixation with 2 (n=112) or 3 (n=41) cannulated screws. The severity of initial displacement was divided into incomplete (type I) and complete (type II, angulation <50 degrees; type III, angulation >50 degrees) fractures. The diameter of the screw was measured and recorded as a percentage of the femoral neck width. The distance (D) between the mid-point of each screw at the base (B) of the femoral neck and at the tip (T) of each screw and the superior and anterior cortices of the femoral neck, respectively, were measured on anteroposterior (AP) and lateral (L) radiographs. Values were expressed as the ratio between the measured distance and the width of the femoral neck (BDAP%, TDAP%, BDL%, and TDL%). The correlation between the number, size, and location of the screws and AVN was analyzed.

RESULTS

Patients with type II of initial displacement treated with 2 cannulated screws had a lower AVN rate (21.4%) than those treated with 3 screws (44.8%) (P=0.027). Screw diameter (19%) in patients with AVN was larger than (17%) in patients without AVN (P<0.001); patients with AVN had a lower BDAP% (48.6%) than those without AVN (56.4%) (P<0.001). Screw size and BDAP% were risk factors for AVN (P<0.05). Further, screw diameter >16.5% and BDAP% <51.6% of the femoral neck width were the cutoff values for an increased AVN rate (P<0.05).

CONCLUSIONS

Patients treated with 2 cannulated screws showed a lower rate of AVN than patients treated with 3 screws. Screws of larger size and screws closer to the piriformis fossa on AP radiographs increased the risk of AVN in children with femoral neck fractures treated surgically.

LEVEL OF EVIDENCE: Level III.

Для цитирования: Wang Wentao, Li Yiqiang, Xiong Zhu, Guo Yueming, Li Ming, Mei Haibo, Shao Jingfan, Li Jin, Canavese Federico, Chen Shunyou. Effect of the Number, Size, and Location of Cannulated Screws on the Incidence of Avascular Necrosis of the Femoral Head in Pediatric Femoral Neck Fractures: A Review of 153 Cases.. Journal of pediatric orthopedics. 2022. DOI: 10.1097/bpo.0000000000002018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.