MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12891-023-06405-x

Медицинская библиотека · BMC musculoskeletal disorders · 2023

Application of nano-hydroxyapatite matrix graft in inter-vertebral fusion therapy: a meta-analysis.

Zhang Kui, Zhu Yandong, Wang Wenji

МетаанализСтатьяПеревод в очереди

Аннотация

OBJECTIVE

Nano-hydroxyapatite and its composites(nHA) have been widely used as grafts in inter-vertebral fusion. However, the safety and efficacy of the graft in inter-vertebral fusion is controversial. This meta-analysis aimed at evaluating the safety and efficacy of nHA and non-hydroxyapatite grafts (noHA) (autologous bone, etc.) in inter-body fusion.

MATERIALS AND

METHODS

A comprehensive search was performed in electronic database as follows: PubMed, EMBASE, the Cochrane Library, Web of Science, and China National Knowledge Internet (CNKI) from inception until October 2022. Clinical studies on the effect of nHA and noHA in spinal fusion were collected. Analysis of outcome indicators using RevMan 5.4 statistical software.

RESULTS

The meta-analysis showed that the operation time of patients who underwent inter-body fusion with nHA grafts was less than that of patients who underwent noHA (p < 0.05). Compared with the noHA group, the nHA group can achieve similar clinical effects in the fusion rate(OR = 1.29,95%CI: 0.88 to 1.88,p = 0.19),Subsidence rate(OR = 1.2,95%CI:0.44 to 3.28,p = 0.72), inter-vertebral space height(SMD = 0.04,95%CI:-0.08 to 0.15,p = 0.54),Cobb angle(SMD = 0.21,95%CI: 0.18 to 0.6,p = 0.21),Blood loss(SMD = -36.58,95%CI: -81.45 to 8.29,p = 0.11),operative time in 12 months(SMD = -5.82,95%CI: -9.98 to -1.67,p = 0.006) and in the final follow-up(SMD = -0.38,95%CI: -0.51 to -0.26,p < 0.00001),ODI(SMD = 0.68,95%CI: -0.84 to 2.19,p = 0.38), VAS(SMD = 0.17,95%CI: -0.13 to 0.48,p = 0.27) and adverse events(OR = 0.98,95%CI: 0.66 to 1.45,p = 0.92), and the differences are not statistically significant.

CONCLUSION

This meta-analysis suggests that nHA matrix grafts are similar to noHA grafts in the safety and efficacy of spinal reconstruction, and are an ideal material for inter-vertebral bone grafting.

Для цитирования: Zhang Kui, Zhu Yandong, Wang Wenji. Application of nano-hydroxyapatite matrix graft in inter-vertebral fusion therapy: a meta-analysis.. BMC musculoskeletal disorders. 2023. DOI: 10.1186/s12891-023-06405-x.