Removal of a Floating and Migrated Plate Screw in a Patient with a Failed Anterior Cervical Discectomy and Fusion.

Lavadi Raj Swaroop, Gajjar Avi A, Elsayed Galal A, Desai Rupen R, Mitha Rida, Puram Sidharth V, Agarwal Nitin

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Anterior cervical discectomy and fusion (ACDF) is a commonly performed procedure for degenerative cervical spine disease. Rare complications of ACDF surgery include hardware failure, in the form of screw loosening and migration, or rod breakage. We present a case in which we removed a migrated screw lodged in the esophagus from a patient with a failed anterior cervical fusion.

OBJECTIVE

To present a surgical technique and considerations to remove a migrated screw.

METHODS

The previous ACDF incision was reopened and exposure was gained under the guidance of a head and neck surgeon. Longus coli were mobilized off the spine bilaterally with electrocautery. After dissection, the screw was found lodged in the longitudinal muscle of the esophageal wall and excised with the use of a 15-blade. The integrity of the esophageal mucosa and submucosa was maintained and subsequently checked with rigid esophagoscopy. Fluoroscopy was used to confirm that all hardware was removed, with the exception of the anterior cages.

RESULTS

The dislodged screw, which was embedded in the esophagus, was successfully removed.

CONCLUSIONS

Failure of an ACDF carries a risk of screw migration, which may be asymptomatic even if the screw is lodged in the esophagus. Additional considerations are required with potential violations of the adjacent viscera.

Для цитирования: Lavadi Raj Swaroop, Gajjar Avi A, Elsayed Galal A, Desai Rupen R, Mitha Rida, Puram Sidharth V, Agarwal Nitin. Removal of a Floating and Migrated Plate Screw in a Patient with a Failed Anterior Cervical Discectomy and Fusion.. World neurosurgery. 2023. DOI: 10.1016/j.wneu.2023.03.101.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.