MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.wneu.2023.03.062

Медицинская библиотека · World neurosurgery · 2023

Intraoperative Cone-Beam Computed Tomography Assessment of Spinal Pedicle Screws Placement Precision Is in Full Agreement with Postoperative Computed Tomography Assessment.

Ohashi Hiroki, Kawamura Daichi, Hatano Keisuke, Ohashi So, Tochigi Satoru, Isoshima Akira, Nagashima Hiroyasu, Otani Katharina, Karagiozov Kostadin, Tani Satoshi, Murayama Yuichi

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To assess agreement between pedicle screw placement evaluated on postoperative computed tomography (CT) and on intraoperative cone-beam CT (CBCT) and compare procedure characteristics when using first-generation and second-generation robotic C-arm systems in the hybrid operating room.

METHODS

All patients who received pedicle screws for spinal fusion at our institution between June 2009 and September 2019 and underwent intraoperative CBCT and postoperative CT were included. The CBCT and CT images were reviewed by 2 surgeons to assess the screw placement using the Gertzbein-Robbins and the Heary classifications. Intermethod agreement of screw placement classifications as well as interrater agreement were assessed using Brennan-Prediger and Gwet agreement coefficients. Procedure characteristics using first-generation and second-generation generation robotic C-arm systems were compared.

RESULTS

Fifty-seven patients were treated with 315 pedicle screws at thoracic, lumbar, and sacral levels. No screw had to be repositioned. On CBCT, accurate placement was found for 309 screws (98.1%) using the Gertzbein-Robbins classification and 289 (91.7%) using the Heary classification and on CT, these were 307 (97.4%) and 293 (93.0%), respectively. Intermethod between CBCT and CT and interrater agreements between the 2 raters were almost perfect (>0.90) for all assessment. There were no significant differences in mean radiation dose (P = 0.83) and fluoroscopy time (P = 0.82), but length of surgery using the second-generation system was estimated at 107.7 minutes (95% confidence interval, 31.9-183.5 minutes; P = 0.006) shorter.

CONCLUSIONS

Intraoperative CBCT provides accurate assessment of pedicle screw placement and enables intraoperative repositioning of misplaced screws.

Для цитирования: Ohashi Hiroki, Kawamura Daichi, Hatano Keisuke, Ohashi So, Tochigi Satoru, Isoshima Akira, Nagashima Hiroyasu, Otani Katharina, Karagiozov Kostadin, Tani Satoshi, Murayama Yuichi. Intraoperative Cone-Beam Computed Tomography Assessment of Spinal Pedicle Screws Placement Precision Is in Full Agreement with Postoperative Computed Tomography Assessment.. World neurosurgery. 2023. DOI: 10.1016/j.wneu.2023.03.062.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.