MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jhsa.2010.11.045

Медицинская библиотека · The Journal of hand surgery · 2011

Anatomical study of the A1 pulley: length and location by means of cutaneous landmarks on the palmar surface.

Fiorini Haroldo J, Santos João B G, Hirakawa Celso K, Sato Edson S, Faloppa Flávio, Albertoni Walter M

СтатьяПеревод в очереди

Аннотация

PURPOSE: The objectives of this study were to evaluate palmar surface parameters to identify the exact location of the proximal edge of the flexor tendon A1 pulley relative to the digital palmar crease of the index, middle, ring, and little fingers and to evaluate the length of this pulley.

METHODS

We studied 280 fingers on 70 hands from 35 fresh human cadavers, initially by measuring the distance between the digital-palmar and proximal interphalangeal creases (measure A), followed by dissection of the fingers and measurement of the distance between the proximal edge of the A1 pulley and the digital-palmar crease (measure B) and the length of the A1 pulley (measure C). We carried out statistical analysis using Hotelling's multivariate T(2)-test and the paired-samples t-test.

RESULTS

We found no statistically significant difference between measures A and B in each finger (p > .05). The mean lengths, in tenths of millimeters, were as follows: measure A: index finger 22.0 mm, middle finger 24.4 mm, ring finger 22.0 mm, and little finger 17.9 mm; measure B: index finger 21.9 mm, middle finger 24.2 mm, ring finger 22.3 mm, and little finger 18.1 mm. The average lengths of the A1 pulley were: index finger 9.8 mm, middle finger 10.7 mm, ring finger 9.6 mm, and little finger 8.1 mm.

CONCLUSIONS

The distance between the digital-palmar and proximal interphalangeal creases may be used as a cutaneous landmark on the palmar surface for the exact location of the proximal edge of the A1 pulley in the palm of the hand, thereby ensuring greater safety in surgical procedures such as percutaneous release of trigger finger.

Для цитирования: Fiorini Haroldo J, Santos João B G, Hirakawa Celso K, Sato Edson S, Faloppa Flávio, Albertoni Walter M. Anatomical study of the A1 pulley: length and location by means of cutaneous landmarks on the palmar surface.. The Journal of hand surgery. 2011. DOI: 10.1016/j.jhsa.2010.11.045.