A digital microfluidic system for serological immunoassays in remote settings.

Ng Alphonsus H C, Fobel Ryan, Fobel Christian, Lamanna Julian, Rackus Darius G, Summers Aimee, Dixon Christopher, Dryden Michael D M, Lam Charis, Ho Man, Mufti Nooman S, Lee Victor, Asri Mohd Afiq Mohd, Sykes Edward A, Chamberlain M Dean, Joseph Rachael, Ope Maurice, Scobie Heather M, Knipes Alaine, Rota Paul A, Marano Nina, Chege Paul M, Njuguna Mary, Nzunza Rosemary, Kisangau Ngina, Kiogora John, Karuingi Michael, Burton John Wagacha, Borus Peter, Lam Eugene, Wheeler Aaron R

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Serosurveys are useful for assessing population susceptibility to vaccine-preventable disease outbreaks. Although at-risk populations in remote areas could benefit from this type of information, they face several logistical barriers to implementation, such as lack of access to centralized laboratories, cold storage, and transport of samples. We describe a potential solution: a compact and portable, field-deployable, point-of-care system relying on digital microfluidics that can rapidly test a small volume of capillary blood for disease-specific antibodies. This system uses inexpensive, inkjet-printed digital microfluidic cartridges together with an integrated instrument to perform enzyme-linked immunosorbent assays (ELISAs). We performed a field validation of the system's analytical performance at Kakuma refugee camp, a remote setting in northwestern Kenya, where we tested children aged 9 to 59 months and caregivers for measles and rubella immunoglobulin G (IgG). The IgG assays were determined to have sensitivities of 86% [95% confidence interval (CI), 79 to 91% (measles)] and 81% [95% CI, 73 to 88% (rubella)] and specificities of 80% [95% CI, 49 to 94% (measles)] and 91% [95% CI, 76 to 97% (rubella)] (measles, n = 140; rubella, n = 135) compared with reference tests (measles IgG and rubella IgG ELISAs from Siemens Enzygnost) conducted in a centralized laboratory. These results demonstrate a potential role for this point-of-care system in global serological surveillance, particularly in remote areas with limited access to centralized laboratories.

Для цитирования: Ng Alphonsus H C, Fobel Ryan, Fobel Christian, Lamanna Julian, Rackus Darius G, Summers Aimee, Dixon Christopher, Dryden Michael D M, Lam Charis, Ho Man, Mufti Nooman S, Lee Victor, Asri Mohd Afiq Mohd, Sykes Edward A, Chamberlain M Dean, Joseph Rachael, Ope Maurice, Scobie Heather M, Knipes Alaine, Rota Paul A, Marano Nina, Chege Paul M, Njuguna Mary, Nzunza Rosemary, Kisangau Ngina, Kiogora John, Karuingi Michael, Burton John Wagacha, Borus Peter, Lam Eugene, Wheeler Aaron R. A digital microfluidic system for serological immunoassays in remote settings.. Science translational medicine. 2018. DOI: 10.1126/scitranslmed.aar6076.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.