MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10140-024-02244-y

Медицинская библиотека · Emergency radiology · 2024

Predictive value of joint fluid volume on advanced pre-procedure imaging related to success of arthrocentesis and presence of septic arthritis.

Miley Lindsey K, Boyum James H, McDonald Jennifer S, Horst Kelly K, Howe Benjamin M, Ringler Michael D

СтатьяПеревод в очереди

Аннотация

PURPOSE: Septic arthritis is a dangerous medical condition requiring prompt diagnosis, often via arthrocentesis. A "dry tap" occurs when no fluid is aspirated. We hypothesized that the absence of a joint effusion on pre-procedure advanced imaging would reliably predict a dry tap and exclude septic arthritis.

METHODS

A cohort of 217 arthrocentesis cases of large joints (hips, shoulders, knees) from our institution, with pre-procedure advanced imaging (CT, MR, US) of the same joint performed within the previous 48 h, was analyzed. Exclusion criteria included non-native joints or inadequate imaging of the affected joint. These cases underwent blinded review by 4 radiologists who measured the deepest pocket of joint fluid on the pre-procedure imaging. Wilcoxon rank-sum test was performed comparing joint fluid pocket size to outcomes of successful aspiration and final diagnosis.

RESULTS

A smaller average joint pocket fluid size was present on advanced imaging in both dry taps compared with successful arthrocenteses (p < .0001), and in uninfected joints compared with septic joints (p = .0001). However, the overlap of values was too great to allow for a perfectly predictive cutoff. 29% (5/17) of patients with no visible joint fluid on pre-aspiration imaging underwent successful arthrocentesis, one case representing septic arthritis.

CONCLUSION

Volume of joint fluid on advanced pre-arthrocentesis imaging cannot reliably predict subsequent dry tap nor exclude septic arthritis.

Для цитирования: Miley Lindsey K, Boyum James H, McDonald Jennifer S, Horst Kelly K, Howe Benjamin M, Ringler Michael D. Predictive value of joint fluid volume on advanced pre-procedure imaging related to success of arthrocentesis and presence of septic arthritis.. Emergency radiology. 2024. DOI: 10.1007/s10140-024-02244-y.