A randomised RSA study of Peri-Apatite HA coating of a total knee prosthesis.

Hansson Ulrik, Ryd Leif, Toksvig-Larsen Sören

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

BACKGROUND

In total knee replacement, sound early fixation of the prosthesis is crucial for achieving a good long-term result and for minimising the risk of loosening. Various types of prosthetic material, different surface textures and shapes and the incorporation of screws or pegs have been used to achieve good fixation, particularly in the uncemented knee. Hydroxyapatite (HA) coating of prosthetic joint components is another technique used to enhance early stability and so to improve the longevity of the prosthesis-bone fixation. HA ceramic coatings are mostly plasma sprayed onto the fixation surface of the implant. Plasma spraying is largely a 'line of sight' technique and as such there are difficulties involved when covering three-dimensional planes, such as porous beaded fixation surfaces typically found on several knee prostheses. The objective of this study was to assess the clinical performance of the solution-deposited HA coating, Peri-Apatite , with regard to its ability to stimulate an endurable and stable implant fixation.

PATIENTS AND

METHODS

We randomised 60 patients into two groups; one group received the porous coated prosthesis with solution-deposited HA, and the other group received a prosthesis without HA. Radiostereometric examination was used as the primary tool for measuring migration in the prosthetic components.

RESULTS

There was a lower incidence of early subsidence in the Peri-Apatite group. At 24 months there were no differences in clinical scorings or maximal total point motion.

CONCLUSION

Addition of solution-deposited HA coating appears to provide better early stable fixation in a porous coated knee prosthesis.

Для цитирования: Hansson Ulrik, Ryd Leif, Toksvig-Larsen Sören. A randomised RSA study of Peri-Apatite HA coating of a total knee prosthesis.. The Knee. 2008. DOI: 10.1016/j.knee.2008.01.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.