MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00064-022-00794-3

Медицинская библиотека · Operative Orthopadie und Traumatologie · 2022

[Intraoperative computed tomography-guided navigation for implant anchorage in spine surgery].

Kothe Ralph, Schmeiser Gregor

Аннотация на английскомСтатьяОбзорПеревод в очереди

Аннотация

OBJECTIVE

Improved accuracy of spinal instrumentation with the use of intraoperative CT (iCT).

INDICATIONS: All types of posterior spinal instrumentation.

CONTRAINDICATIONS: None.

SURGICAL TECHNIQUE: After fixation of the spinal clamp, an intraoperative CT (iCT) is performed. The image data set can then be used for navigation of the spinal implants. The arrangement of the devices, positioning of the patient, and the exact fixation of the clamp depend on the operation technique and the anatomical region. A high level of standardization is necessary for clinical success. In general, the utilization of drill guides over the use of awls and Yamshidi needles is strongly recommended. Thereby the risk of segmental vertebral rotation, especially in multisegmental instrumentation, will be reduced.

POSTOPERATIVE MANAGEMENT: The postoperative management depends on the type of surgery and is not influenced by the use of navigation with iCT.

RESULTS

In our patient group of the first 200 surgeries with iCT (AIRO, Brainlab AG, Munich, Germany), we performed 34% cervical instrumentations, 31% percutaneous screw insertions, and 35% multisegmental open procedures including the sacrum or ilium. Two surgeries had to be converted to conventional technique due to technical problems. One misplaced S2/Ala/ilium screw had to be corrected in revision surgery. The infection rate was 2.5% and was not increased compared to conventional procedures. In the literature, a significant reduction of radiation exposure was shown, when iCT and navigation were used. Also, in longer surgical cases the operation time could be reduced. In comparison with 3D C‑arm imaging, the image quality and screw accuracy is improved by iCT. Due to the possibility of 3D intraoperative implant control, the number of revision cases can be reduced.

Для цитирования: Kothe Ralph, Schmeiser Gregor. [Intraoperative computed tomography-guided navigation for implant anchorage in spine surgery].. Operative Orthopadie und Traumatologie. 2022. DOI: 10.1007/s00064-022-00794-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.