MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0049726

Медицинская библиотека · PloS one · 2012

Improved flow cytometric assessment reveals distinct microvesicle (cell-derived microparticle) signatures in joint diseases.

György Bence, Szabó Tamás G, Turiák Lilla, Wright Matthew, Herczeg Petra, Lédeczi Zsigmond, Kittel Agnes, Polgár Anna, Tóth Kálmán, Dérfalvi Beáta, Zelenák Gergő, Böröcz István, Carr Bob, Nagy György, Vékey Károly, Gay Steffen, Falus András, Buzás Edit I

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

INTRODUCTION

Microvesicles (MVs), earlier referred to as microparticles, represent a major type of extracellular vesicles currently considered as novel biomarkers in various clinical settings such as autoimmune disorders. However, the analysis of MVs in body fluids has not been fully standardized yet, and there are numerous pitfalls that hinder the correct assessment of these structures.

METHODS

In this study, we analyzed synovial fluid (SF) samples of patients with osteoarthritis (OA), rheumatoid arthritis (RA) and juvenile idiopathic arthritis (JIA). To assess factors that may confound MV detection in joint diseases, we used electron microscopy (EM), Nanoparticle Tracking Analysis (NTA) and mass spectrometry (MS). For flow cytometry, a method commonly used for phenotyping and enumeration of MVs, we combined recent advances in the field, and used a novel approach of differential detergent lysis for the exclusion of MV-mimicking non-vesicular signals.

RESULTS

EM and NTA showed that substantial amounts of particles other than MVs were present in SF samples. Beyond known MV-associated proteins, MS analysis also revealed abundant plasma- and immune complex-related proteins in MV preparations. Applying improved flow cytometric analysis, we demonstrate for the first time that CD3(+) and CD8(+) T-cell derived SF MVs are highly elevated in patients with RA compared to OA patients (p=0.027 and p=0.009, respectively, after Bonferroni corrections). In JIA, we identified reduced numbers of B cell-derived MVs (p=0.009, after Bonferroni correction).

CONCLUSIONS

Our results suggest that improved flow cytometric assessment of MVs facilitates the detection of previously unrecognized disease-associated vesicular signatures.

Для цитирования: György Bence, Szabó Tamás G, Turiák Lilla, Wright Matthew, Herczeg Petra, Lédeczi Zsigmond, Kittel Agnes, Polgár Anna, Tóth Kálmán, Dérfalvi Beáta, Zelenák Gergő, Böröcz István, Carr Bob, Nagy György, Vékey Károly, Gay Steffen, Falus András, Buzás Edit I. Improved flow cytometric assessment reveals distinct microvesicle (cell-derived microparticle) signatures in joint diseases.. PloS one. 2012. DOI: 10.1371/journal.pone.0049726.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.