Effectiveness of leucocyte esterase as a diagnostic test for acute septic arthritis.
Аннотация
BACKGROUND
We hypothesized that leucocyte esterase strip test can aid in diagnosing septic arthritis in native synovial fluid because leucocyte esterase concentrations would be elevated at the infection site because of secretion by recruited neutrophils.
METHOD: The cohort included 27 patients (suspected septic arthritis and normal subjects). A standard chemical test strip (graded as negative, trace, +, ++ or +++) was used to detect the presence of leucocyte esterase. Fluid leucocyte count, Gram staining, culture, erythrocyte sedimentation rate and C-reactive protein were also assessed.
RESULTS
The leucocyte esterase test with a threshold of ++/+++ had a sensitivity of 79.2% (95% CI [confidence interval], 65.9% to 89.2%), specificity of 80.8% (95% CI, 73.3% to 87.1%), positive predictive value (PPV) of 61.8% (95% CI, 49.2% to 73.3%) and negative predictive value (NPV) of 90.1% (95% CI, 84.3% to 95.4%).
CONCLUSION
The leucocyte esterase strip test yielded a high specificity, PPV, NPV, high sensitivity and high diagnostic accuracy. Leucocyte esterase is an accurate, quick and bedside test for septic arthritis and can be used effectively for diagnosing periprosthetic joint infections along with other battery of tests according to the Musculoskeletal Infection Society criteria.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.