The Anterior Modified San Diego Acetabuloplasty Does Not Increase Superior-Anterior Coverage in Patient-Specific 3D-Printed Models.

Tadlock Joshua C, Rupp Garrett E, Farnsworth Christine L, Bomar James D, Caffrey Jason P, Upasani Vidyadhar V

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Patients with developmental dysplasia of the hip may require pelvic osteotomies to improve acetabular coverage. The purpose of this study was to compare the changes in acetabular version, tilt, and regional coverage angles following the San Diego acetabuloplasty (SDA), the modified San Diego acetabuloplasty (mSDA), and the Pemberton acetabuloplasty (PA).

METHODS

Fourteen patients with developmental dysplasia of the hip and computed tomography (CT) imaging were identified. From CT images, 2 identical pelvises were 3-dimensional-printed for each patient. Bone was printed with rigid material, and cartilage with flexible material. For each model pair, the SDA was performed on one and the PA was performed on the other. CT scans were obtained before and after acetabuloplasties. Next, the bone graft in the SDA model was moved anteriorly, representing the mSDA, and the model was rescanned. Acetabular version, tilt, and coverage angles (posterior, superior-posterior, superior, superior-anterior, and anterior) were calculated. Preoperative to postoperative differences were compared (repeated measures analysis of variance or Wilcoxon signed rank test). The significance was set to P <0.05.

RESULTS

The mean age at CT was 5.8±1.2 years (range: 3.9 to 7.5 y). All 3 procedures (SDA, mSDA, and PA) significantly increased acetabular tilt; P <0.045), with a similar change observed for all 3 ( P =0.868). PA was the only procedure to significantly decrease relative acetabular version (6.5±6.5 degrees, preoperative: 12.9±5.3 degrees; P =0.004). Both the SDA and mSDA procedures significantly increased coverage in the superior-posterior octant (SDA: 92.6±9.3 degrees, mSDA: 92.3±9.8 degrees, preoperative: 81.9±9.5 degrees; P <0.02), with a similar percent change among the 2 ( P =1.0). All 3 procedures significantly increased superior coverage ( P <0.04); the increase was similar among the 3 ( P =0.205). The PA was the only procedure to produce a significant increase in coverage in the superior-anterior octant (91.0±16.7 degrees, preoperative: 74.0±12.1 degrees; P =0.005) or the anterior octant (50.7±11.7 degrees, preoperative: 45.8±8.9 degrees; P =0.012).

CONCLUSIONS

The SDA and mSDA procedures produced similar postoperative changes, primarily in the superior and superior-posterior acetabular octants. Placing the graft more anteriorly did not increase anterior coverage in the mSDA, and only the PA increased coverage in the superior and superior-anterior acetabular octants.

Для цитирования: Tadlock Joshua C, Rupp Garrett E, Farnsworth Christine L, Bomar James D, Caffrey Jason P, Upasani Vidyadhar V. The Anterior Modified San Diego Acetabuloplasty Does Not Increase Superior-Anterior Coverage in Patient-Specific 3D-Printed Models.. Journal of pediatric orthopedics. 2024. DOI: 10.1097/bpo.0000000000002640.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.