Huddleston Hailey P, Kurtzman Joey S, Deegan Liam, Hayes Westley, Austin Kevin, Carter John, Aibinder William R, Koehler Steven M
Аннотация
BACKGROUND: The purpose of this study was to perform a biomechanical investigation on the effect of ulnar variance (UV) on the stability of the distal radioulnar joint (DRUJ) prior to and after DRUJ sectioning.
METHODS: Ten cadaveric forearm specimens were included in the study and baseline UV was assessed radiographically. Radial motion relative to the ulna was evaluated using Intel real sense cameras and a custom developed program. The forearms were dissected, and a radial osteotomy was performed. Using a custom-made plate, radial stability was assessed with an UV of + 4, 0, and -4 mm by measuring the maximum and minimum radial position relative to the ulna during a simulated Shuck test. The volar radioulnar ligaments and triangular fibrocartilage complex (TFCC) were then sectioned, and testing was repeated at each UV state.
RESULTS: Sectioning significantly increased radial translation at neutral (P = .008), +4 mm UV (P = .008), and -4 mm UV (P = .018). There were no significant differences in translation between the 3 UV groups with the DRUJ intact (P = .124). The ulnar negative (-4 mm) state had significantly lower translation compared to the positive (+4 mm) (P < .001) and the neutral (0 mm) (P = .026) UV states. There were no significant differences between the positive and neutral UV groups with the DRUJ sectioned.
CONCLUSIONS: Fixating the radius in -4 mm of ulnar negativity significantly decreased radial translation after sectioning the volar radioulnar ligament and TFCC. Ulnar variance had no effect on stability with an intact DRUJ.
STUDY TYPE: Biomechanical Study.
METHODS: Ten cadaveric forearm specimens were included in the study and baseline UV was assessed radiographically. Radial motion relative to the ulna was evaluated using Intel real sense cameras and a custom developed program. The forearms were dissected, and a radial osteotomy was performed. Using a custom-made plate, radial stability was assessed with an UV of + 4, 0, and -4 mm by measuring the maximum and minimum radial position relative to the ulna during a simulated Shuck test. The volar radioulnar ligaments and triangular fibrocartilage complex (TFCC) were then sectioned, and testing was repeated at each UV state.
RESULTS: Sectioning significantly increased radial translation at neutral (P = .008), +4 mm UV (P = .008), and -4 mm UV (P = .018). There were no significant differences in translation between the 3 UV groups with the DRUJ intact (P = .124). The ulnar negative (-4 mm) state had significantly lower translation compared to the positive (+4 mm) (P < .001) and the neutral (0 mm) (P = .026) UV states. There were no significant differences between the positive and neutral UV groups with the DRUJ sectioned.
CONCLUSIONS: Fixating the radius in -4 mm of ulnar negativity significantly decreased radial translation after sectioning the volar radioulnar ligament and TFCC. Ulnar variance had no effect on stability with an intact DRUJ.
STUDY TYPE: Biomechanical Study.