MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13018-022-02917-9

Медицинская библиотека · Journal of orthopaedic surgery and research · 2022

Application of a new integrated low-profile anterior plate and cage system in single-level cervical spondylosis: a preliminary retrospective study.

Wei Leixin, Xu Chen, Dong Minjie, Dou Yibo, Tian Ye, Wu Huiqiao, Wu Xiaodong, Wang Xinwei, Chen Huajiang, Shen Xiaolong, Cao Peng, Yuan Wen

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Although ACDF has been widely used in treating cervical spondylosis and related diseases, the complications along with this anterior surgical technique have hindered its application and affected the postoperative outcome of the patients. Here, we investigated the clinical and radiological outcomes of a new integrated low-profile anterior plate and cage system for anterior cervical discectomy and fusion (ACDF) in treating cervical spondylosis.

METHODS

A total of 96 cervical spondylosis patients who underwent single-level ACDF between 2018 to 2020 in our institute were enrolled. There were 28 patients using the new implants and 68 patients using the zero-profile (Zero-P) implants. The Japanese Orthopedic Association (JOA) score and the visual analog scale (VAS) were used to evaluate the clinical outcomes. The cervical and segmental Cobb angle and range of motion (ROM) were used to assessed the radiological outcomes. Incidence of complications were also recorded. All data were recorded at pre-operation, 6-month and 12-month post-operation.

RESULTS

All patients were followed-up for at least 1-year, the mean follow-up time was over one year. The fusion rate was similar in the two groups. There was no significant difference in the postoperative JOA score recovery rate, postoperative VAS score of neck and arm pain, postoperative ROM, and incidence of complications between two groups (P > 0.05). However, postoperative cervical and segmental Cobb angle were better maintained in the new low-profile implant group compared to Zero-P group.

CONCLUSIONS

The clinical outcomes of the new low-profile implant were satisfactory and comparable to that of zero-profile system. It may have advantages in improving and maintaining the cervical lordosis, and can be an alternative device for single-level cervical spondylosis treated with ACDF.

Для цитирования: Wei Leixin, Xu Chen, Dong Minjie, Dou Yibo, Tian Ye, Wu Huiqiao, Wu Xiaodong, Wang Xinwei, Chen Huajiang, Shen Xiaolong, Cao Peng, Yuan Wen. Application of a new integrated low-profile anterior plate and cage system in single-level cervical spondylosis: a preliminary retrospective study.. Journal of orthopaedic surgery and research. 2022. DOI: 10.1186/s13018-022-02917-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.