MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-022-04491-5

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2022

Arthroscopic rod technique compared to stress ultrasound in the dynamic evaluation of lateral ligament instabilities of the elbow.

Plath Johannes, Otto Alexander, Förch Stefan, Siebenlist Sebastian, Grosser Bianca, Mayr Edgar, Imhoff Andreas B, Lenich Andreas

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

The purpose was to compare the arthroscopic rod technique to stress ultrasound in the dynamic assessment of lateral elbow instabilities.

MATERIALS AND

METHODS

Fifteen elbows of eight specimen with a mean age of 66.4 ± 13.3 years were assessed in a prone position following a defined dissection setup. After evaluation of the native status, an arthroscopic dissection of the radial collateral ligament (RCL) or lateral ulnar collateral ligament (LUCL), and finally of entire capsuloligamentous structures was performed. Three raters examined each state (native, RCL or LUCL lesion, complete lesion) with the arthroscopic rod technique in 90° flexion and with stress ultrasound in 30 and 90° flexion. The intra-class correlation coefficient (ICC) was calculated to assess the interrater reliability as well as test-retest reliability for each testing modality (arthroscopy and ultrasound).

RESULTS

The arthroscopic rod technique showed a superior interrater and test-retest reliability of 0.953 and 0.959 (P < 0.001), respectively, when compared to stress ultrasound with an ICC of 0.4 and 0.611 (P < 0.001). A joint space opening during arthroscopy of > 6 mm humero-ulnar or > 7 mm humero-radial was indicative for a lateral collateral ligament lesion. However, a differentiation between an isolated RCL or LUCL tear was not possible. A lateral joint opening of ≥ 9 mm was only observed in complete tears of the lateral capsuloligamentous complex.

CONCLUSIONS

The arthroscopic rod technique showed a superior interrater and test-retest reliability when compared to stress ultrasound. Arthroscopic assessment for radial elbow instability was found to be reliable and reproducible. A joint gapping ≥ 9 mm in the arthroscopic evaluation is a sign for a complete insufficiency of the radial capsuloligamentous complex. However, it is not possible to precisely distinguish between a lesion of the RCL or LUCL by arthroscopy. On the basis of our results, dynamic ultrasound testing may be inappropriate to objectify lateral elbow instability.

Для цитирования: Plath Johannes, Otto Alexander, Förch Stefan, Siebenlist Sebastian, Grosser Bianca, Mayr Edgar, Imhoff Andreas B, Lenich Andreas. Arthroscopic rod technique compared to stress ultrasound in the dynamic evaluation of lateral ligament instabilities of the elbow.. Archives of orthopaedic and trauma surgery. 2022. DOI: 10.1007/s00402-022-04491-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.