Inverted supracondylar femoral dynamic compression plates for revision of construct failure following tibial cranial closing wedge ostectomy in three dogs.
Аннотация
Construct failure is a rare complication of tibial cranial closing wedge ostectomy for the management of cranial cruciate ligament disease. Construct failure can present significant challenges for reconstruction. This case report describes three dogs with construct failure which were successfully revised by the repurposing of an inverted femoral supracondylar femoral plate as part of the revision. Data were obtained from the medical records and telephone update. The use of an inverted supracondylar plate in the proximal tibia generally had good outcomes for the management of bone implant failure following cranial closing wedge ostectomy and offers a hitherto undescribed technique using a low-cost and accessible implant for repair.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.