MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-022-04432-2

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2022

Biomechanical evaluation of interference screw fixation techniques for distal radioulnar ligament reconstruction: a cadaveric experimental study.

Gu Fengming, Fang Xiaodong, Zhao Gang, Pan Xiaoyun, Xiong Fei, Ying Qiuwen, Mi Jingyi

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

INTRODUCTION

In the reconstruction of distal radioulnar ligaments (DRULs), interference screws can be used for antegrade or retrograde fixation of grafts to the ulna. However, the biomechanics of interference screw fixation are currently unknown. This study aimed to determine the biomechanical effects of these two fixations on the distal radioulnar joint (DRUJ) in a cadaveric model and to investigate the appropriate initial tension.

MATERIALS AND

METHODS

A total of 30 human cadaver upper extremities were used, and the DRULs were reconstructed according to Adams' procedure. First, eight specimens were randomly divided into two groups: antegrade and retrograde, followed by translational testing and load testing. Then, the other eight specimens were divided into the two groups above, and the contact mechanics, including forces, areas, and pressures, were measured. Finally, to investigate the appropriate initial tension, the remaining 14 specimens were fixed with interference screws under different tensions in an antegrade way, and the translational testing was repeated as before.

RESULTS

In the neutral position, antegrade fixation exhibited less translation than retrograde fixation (7.21 ± 0.17 mm versus 10.77 ± 1.68 mm, respectively). The maximum failure load was 70.45 ± 6.20 N in antegrade fixation, while that in retrograde fixation was 35.17 ± 2.95 N (P < 0.0001). Antegrade fixation exhibited a larger increase in contact force than retrograde fixation (99.72% ± 23.88% versus 28.18% ± 10.43%) (P = 0.001). The relationship between tension and displacement was nonlinear (Y = - 1.877 ln(x) + 7.94, R2 = 0.868, P < 0.0001).

CONCLUSIONS

Compared with retrograde fixation, the antegrade fixation of interference screws may be a more reliable surgical technique, as it shows a higher failure load and stability. In addition, to avoid the risk of potential arthritis caused by anterograde fixation, we propose an equation to determine the appropriate initial tension in DRUL reconstruction.

Для цитирования: Gu Fengming, Fang Xiaodong, Zhao Gang, Pan Xiaoyun, Xiong Fei, Ying Qiuwen, Mi Jingyi. Biomechanical evaluation of interference screw fixation techniques for distal radioulnar ligament reconstruction: a cadaveric experimental study.. Archives of orthopaedic and trauma surgery. 2022. DOI: 10.1007/s00402-022-04432-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.