MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1259/dmfr/28315324

Медицинская библиотека · Dento maxillo facial radiology · 2007

Marginal bone levels measured in film and digital radiographs corrected for attenuation and visual response: an in vivo study.

Li G, Engström P E, Nasström K, Lü Z Y, Sanderink G, Welander U

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare the accuracy and precision of measurements on marginal bone levels in differently processed digital radiographs and in film-based radiographs.

METHODS

Twenty-one patients with a diagnosis of chronic periodontitis were included in this study. Periapical radiographs were exposed with the Dixi digital intraoral radiographic system (Planmeca Oy, Helsinki, Finland) and the F-speed Film (Insight, Eastman-Kodak Co., Rochester, NY), respectively. Digital radiographs were subsequently processed into two sets: (a) correction for attenuation and visual response and (b) the same correction but with an additional shift in grey levels. Patients had periodontal surgery immediately after the radiographs were exposed. The vertical distance from cementoenamel junction to the most apical part of the marginal bone was assessed. The measurements were then employed as reference standard and subtracted by the vertical distance from radiographs accordingly. Altogether, 47 sites were evaluated. Seven observers were employed for evaluation under the same viewing conditions. ANOVA was employed for statistical analysis.

RESULTS

No significant differences were found between the absolute differences of the vertical distance obtained from radiographs to their corresponding reference standards when comparing differently processed digital radiographs, but the absolute differences were significantly smaller in digital radiographs than in films. Interobserver variances were not significant.

CONCLUSION

Digital radiographs have a favourable measurement accuracy compared with film radiographs when assessing marginal bone levels.

Для цитирования: Li G, Engström P E, Nasström K, Lü Z Y, Sanderink G, Welander U. Marginal bone levels measured in film and digital radiographs corrected for attenuation and visual response: an in vivo study.. Dento maxillo facial radiology. 2007. DOI: 10.1259/dmfr/28315324.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.