Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2019

Accuracy of tibial component placement in unicompartmental knee arthroplasty performed using an accelerometer-based portable navigation system.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Matsui Yoshio, Fukuoka Shinichi, Masuda Sho, Matsuura Masanori, Masada Toshiaki, Fukunaga Kenji

Аннотация

PURPOSE: There is a need for new devices to improve the accuracy of implantation in unicompartmental knee arthroplasties (UKAs). The accelerometer-based portable navigation system is expected to improve this accuracy. This study aimed to compare the accuracy of UKAs performed by the portable navigation system with that of the conventional method, and to investigate whether the portable navigation system can complement the surgeon's experience.

METHODS: The study comprised of 80 Oxford UKAs. Knees were divided into two groups based on the method of tibial osteotomy: the conventional group (37 UKAs performed by an experienced surgeon using the extra-medullary guide) and the portable navigation group (43 UKAs performed by 2 unaccustomed surgeons using the navigation system). The absolute error from the target angle on the coronal and sagittal plane was measured on whole lower leg X-ray. The incidence of outliers (> 3°) was compared between the groups using Fisher's exact probability test.

RESULTS: The incidences of outliers on the coronal plane were 41.0% (15 of 37 knees) in the conventional group and 9.3% (4 of 43 knees) in the portable navigation group (p < 0.0001). The incidences of outliers on the sagittal plane were 13.5% (5 of 37 knees) in the conventional group and 14.0% (6 of 43 knees) in the portable navigation group (p = 0.3772).

CONCLUSION: This is the first report on the usefulness of an accelerometer-based portable navigation system in UKA. The use of this system improves the accuracy of implantation of the tibial component beyond the experience of the surgeon.

LEVEL OF EVIDENCE: Retrospective comparative study, Level III.