MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.wneu.2021.12.110

Медицинская библиотека · World neurosurgery · 2022

Pharyngoesophageal Damage from Hardware Extrusion at an Average of 7.5 Years After Anterior Cervical Diskectomy and Fusion: A Case Series, Discussion of Risk Factors, and Guide for Management.

Yahanda Alexander T, Pennicooke Brenton, Ray Wilson Z, Hacker Carl D, Kelly Michael P, Dorward Ian G, Santiago Paul, Molina Camilo A

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

We present a single-institution case series of patients who experienced pharyngoesophageal damage, specifically from extruded hardware occurring at an average of 7.5 years after anterior cervical diskectomy and fusion (ACDF).

METHODS

A retrospective chart review was conducted of patients who had undergone ACDF with subsequent delayed pharyngoesophageal perforation or erosion from extruded hardware ≥1 year after surgery. A discussion of the literature surrounding this complication, including risk factors and management, is also presented.

RESULTS

Nine patients were identified (average age 58 years, 66.7% male) among a total of 4122 ACDF patients (incidence: 0.22%). Average time to injury was 7.5 years. Indications for initial ACDF were degenerative cervical disease (n = 7), ankylosing spondylitis (n = 1), and cervical fracture (n = 1). Eight patients had prior multilevel ACDF spanning 2 (n = 4), 3 (n = 1), or 4 levels (n = 2). Fusion levels for prior ACDF included C5-C7 (n = 3), C3-C7 (n = 2), C4-C7 (n = 1), C4-C6 (n = 1), C2-C5 (n = 1), and C6-C7 (n = 1). Pharyngoesophageal injuries included esophageal perforation (n = 3), pharyngeal perforation (n = 2), esophageal erosion (n = 3), and pharyngoesophageal erosion (n = 1). In most (n = 6) cases, the cause of pharyngoesophageal damage was due to ≥1 extruded screws. Dysphagia (n = 8) was the most common presenting symptom. For perforations (n = 5), 2 repairs used a rotational flap to reinforce a primary closure; the other 3 cases were repaired via primary closure.

CONCLUSIONS

Pharyngoesophageal damage caused by extruded hardware may occur several years after ACDF. These delayed complications are difficult to predict. Proper screw placement may be the most important factor for minimizing the chances of this potentially devastating complication, particularly with multilevel constructs.

Для цитирования: Yahanda Alexander T, Pennicooke Brenton, Ray Wilson Z, Hacker Carl D, Kelly Michael P, Dorward Ian G, Santiago Paul, Molina Camilo A. Pharyngoesophageal Damage from Hardware Extrusion at an Average of 7.5 Years After Anterior Cervical Diskectomy and Fusion: A Case Series, Discussion of Risk Factors, and Guide for Management.. World neurosurgery. 2022. DOI: 10.1016/j.wneu.2021.12.110.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.