DOI 10.1007/s00586-022-07454-x
Effects of a microgravity SkinSuit on lumbar geometry and kinematics.
Аннотация
PURPOSE: Astronauts returning from long ISS missions have demonstrated an increased incidence of lumbar disc herniation accompanied by biomechanical and morphological changes associated with spine elongation. This research describes a ground-based study of the effects of an axial compression countermeasure Mk VI SkinSuit designed to reload the spine and reduce these changes before return to terrestrial gravity.
METHODS
Twenty healthy male volunteers aged 21-36 without back pain participated. Each lay overnight on a Hyper Buoyancy Flotation (HBF) bed for 12 h on two occasions 6 weeks apart. On the second occasion participants donned a Mk VI SkinSuit designed to axially load the spine at 0.2 Gz during the last 4 h of flotation. Immediately after each exposure, participants received recumbent MRI and flexion-extension quantitative fluoroscopy scans of their lumbar spines, measuring differences between spine geometry and intervertebral kinematics with and without the SkinSuit. This was followed by the same procedure whilst weight bearing. Paired comparisons were performed for all measurements.
RESULTS
Following Mk VI SkinSuit use, participants evidenced more flexion RoM at L3-4 (p = 0.01) and L4-5 (p = 0.003), more translation at L3-4 (p = 0.02), lower dynamic disc height at L5-S1 (p = 0.002), lower lumbar spine length (p = 0.01) and greater lordosis (p = 0.0001) than without the Mk VI SkinSuit. Disc cross-sectional area and volume were not significantly affected.
CONCLUSION
The MkVI SkinSuit restores lumbar mobility and lordosis following 4 h of wearing during hyper buoyancy flotation in a healthy control population and may be an effective countermeasure for post space flight lumbar disc herniation.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.