MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/medicina61081342

Медицинская библиотека · Medicina (Kaunas, Lithuania) · 2025

Clinical Failure of General-Purpose AI in Photographic Scoliosis Assessment: A Diagnostic Accuracy Study.

Aydin Cemre, Duygu Ozden Bedre, Karakas Asli Beril, Er Eda, Gokmen Gokhan, Ozturk Anil Murat, Govsa Figen

СтатьяПеревод в очереди

Аннотация

Background and

Objectives

General-purpose multimodal large language models (LLMs) are increasingly used for medical image interpretation despite lacking clinical validation. This study evaluates the diagnostic reliability of ChatGPT-4o and Claude 2 in photographic assessment of adolescent idiopathic scoliosis (AIS) against radiological standards. This study examines two critical questions: whether families can derive reliable preliminary assessments from LLMs through analysis of clinical photographs and whether LLMs exhibit cognitive fidelity in their visuospatial reasoning capabilities for AIS assessment. Materials and

Methods

A prospective diagnostic accuracy study (STARD-compliant) analyzed 97 adolescents (74 with AIS and 23 with postural asymmetry). Standardized clinical photographs (nine views/patient) were assessed by two LLMs and two orthopedic residents against reference radiological measurements. Primary outcomes included diagnostic accuracy (sensitivity/specificity), Cobb angle concordance (Lin's CCC), inter-rater reliability (Cohen's κ), and measurement agreement (Bland-Altman LoA).

Results

The LLMs exhibited hazardous diagnostic inaccuracy: ChatGPT misclassified all non-AIS cases (specificity 0% [95% CI: 0.0-14.8]), while Claude 2 generated 78.3% false positives. Systematic measurement errors exceeded clinical tolerance: ChatGPT overestimated thoracic curves by +10.74° (LoA: -21.45° to +42.92°), exceeding tolerance by >800%. Both LLMs showed inverse biomechanical concordance in thoracolumbar curves (CCC ≤ -0.106). Inter-rater reliability fell below random chance (ChatGPT κ = -0.039). Universal proportional bias (slopes ≈ -1.0) caused severe curve underestimation (e.g., 10-15° error for 50° deformities). Human evaluators demonstrated superior bias control (0.3-2.8° vs. 2.6-10.7°) but suboptimal specificity (21.7-26.1%) and hazardous lumbar concordance (CCC: -0.123).

Conclusions

General-purpose LLMs demonstrate clinically unacceptable inaccuracy in photographic AIS assessment, contraindicating clinical deployment. Catastrophic false positives, systematic measurement errors exceeding tolerance by 480-1074%, and inverse diagnostic concordance necessitate urgent regulatory safeguards under frameworks like the EU AI Act. Neither LLMs nor photographic human assessment achieve reliability thresholds for standalone screening, mandating domain-specific algorithm development and integration of 3D modalities.

Для цитирования: Aydin Cemre, Duygu Ozden Bedre, Karakas Asli Beril, Er Eda, Gokmen Gokhan, Ozturk Anil Murat, Govsa Figen. Clinical Failure of General-Purpose AI in Photographic Scoliosis Assessment: A Diagnostic Accuracy Study.. Medicina (Kaunas, Lithuania). 2025. DOI: 10.3390/medicina61081342.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.