MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/2309499019828515

Медицинская библиотека · Journal of orthopaedic surgery (Hong Kong) · 2019

Reproducibility of pelvic sagittal inclination while acquiring radiographs in supine and standing postures.

Uemura Keisuke, Takao Masaki, Otake Yoshito, Koyama Koki, Yokota Futoshi, Hamada Hidetoshi, Sakai Takashi, Sato Yoshinobu, Sugano Nobuhiko

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: Pelvic position on the sagittal plane is usually evaluated with the pelvic sagittal inclination (PSI) angle from a single radiograph. However, the reproducibility of pelvic positioning has not been investigated, and thus, the validity of measuring the PSI from a single film/time point is not understood. Herein, the reproducibility of a patient's pelvic positions in supine and standing postures was analyzed.

METHODS

A total of 34 patients who underwent either a pelvic osteotomy or total hip arthroplasty were enrolled in this study. Preoperative radiographs in both supine and standing postures were acquired twice (first X-ray and second X-ray) within 6 months; preoperative computed tomography (CT) images of the full pelvis were also acquired in a supine posture (preop-CT). To eliminate measurement variability, each PSI was automatically measured from radiographs and CT images through the use of CT segmentation and landmark localization followed by intensity-based 2D-3D registration. The absolute difference of PSI among each image was calculated and the intra-class correlation coefficient (ICC) in each posture was also analyzed.

RESULTS

The median absolute differences of PSI in the supine posture were 1.3° between the first and second X-rays, 1.2° between the first X-ray and preop-CT, and 1.3° between the second X-ray and preop-CT. The median absolute difference of PSI in the standing posture was 1.5°. The ICC was 0.965 (95% CI: 0.939-0.981) in supine and 0.977 (95% CI: 0.954-0.988) during standing.

CONCLUSIONS

Pelvic positions in supine and standing postures are reproducible. Thus, measuring the PSI from a single radiograph is reliable.

Для цитирования: Uemura Keisuke, Takao Masaki, Otake Yoshito, Koyama Koki, Yokota Futoshi, Hamada Hidetoshi, Sakai Takashi, Sato Yoshinobu, Sugano Nobuhiko. Reproducibility of pelvic sagittal inclination while acquiring radiographs in supine and standing postures.. Journal of orthopaedic surgery (Hong Kong). 2019. DOI: 10.1177/2309499019828515.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.