Vassileva Jenia, Rehani Madan M, Al-Dhuhli Humoud, Al-Naemi Huda M, Al-Suwaidi Jamila Salem, Appelgate Kimberly, Arandjic Danijela, Bashier Einas Hamed Osman, Beganovic Adnan, Benavente Tony, Bieganski Tadeusz, Dias Simone, El-Nachef Leila, Faj Dario, Gamarra-Sánchez Mirtha E, Garcia-Aguilar Juan, Gbelcová L'ubka, Gershan Vesna, Gershkevitsh Eduard, Gruppetta Edward, Hustuc Alexandru, Ivanovic Sonja, Jauhari Arif, Kharita Mohammad Hassan, Kharuzhyk Siarhei, Khelassi-Toutaoui Nadia, Khosravi Hamid Reza, Khoury Helen, Kostova-Lefterova Desislava, Kralik Ivana, Liu Lantao, Mazuoliene Jolanta, Mora Patricia, Muhogora Wilbroad, Muthuvelu Pirunthavany, Novak Leos, Pallewatte Aruna S, Shaaban Mohamed, Shelly Esti, Stepanyan Karapet, Teo Eu-Leong Harvey J, Thelsy Naw, Visrutaratna Pannee, Zaman Areesha, Zontar Dejan

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

OBJECTIVE

The purpose of this study was to assess the frequency of pediatric CT in 40 less-resourced countries and to determine the level of appropriateness in CT use.

MATERIALS AND

METHODS

Data on the increase in the number of CT examinations during 2007 and 2009 and appropriate use of CT examinations were collected, using standard forms, from 146 CT facilities at 126 hospitals.

RESULTS

The lowest frequency of pediatric CT examinations in 2009 was in European facilities (4.3%), and frequencies in Asia (12.2%) and Africa (7.8%) were twice as high. Head CT is the most common CT examination in children, amounting to nearly 75% of all pediatric CT examinations. Although regulations in many countries assign radiologists with the main responsibility of deciding whether a radiologic examination should be performed, in fact, radiologists alone were responsible for only 6.3% of situations. Written referral guidelines for imaging were not available in almost one half of the CT facilities. Appropriateness criteria for CT examinations in children did not always follow guidelines set by agencies, in particular, for patients with accidental head trauma, infants with congenital torticollis, children with possible ventriculoperitoneal shunt malfunction, and young children (< 5 years old) with acute sinusitis. In about one third of situations, nonavailability of previous images and records on previously received patient doses have the potential to lead to unnecessary examinations and radiation doses.

CONCLUSION

With increasing use of CT in children and a lack of use of appropriateness criteria, there is a strong need to implement guidelines to avoid unnecessary radiation doses to children.

Для цитирования: Vassileva Jenia, Rehani Madan M, Al-Dhuhli Humoud, Al-Naemi Huda M, Al-Suwaidi Jamila Salem, Appelgate Kimberly, Arandjic Danijela, Bashier Einas Hamed Osman, Beganovic Adnan, Benavente Tony, Bieganski Tadeusz, Dias Simone, El-Nachef Leila, Faj Dario, Gamarra-Sánchez Mirtha E, Garcia-Aguilar Juan, Gbelcová L'ubka, Gershan Vesna, Gershkevitsh Eduard, Gruppetta Edward, Hustuc Alexandru, Ivanovic Sonja, Jauhari Arif, Kharita Mohammad Hassan, Kharuzhyk Siarhei, Khelassi-Toutaoui Nadia, Khosravi Hamid Reza, Khoury Helen, Kostova-Lefterova Desislava, Kralik Ivana, Liu Lantao, Mazuoliene Jolanta, Mora Patricia, Muhogora Wilbroad, Muthuvelu Pirunthavany, Novak Leos, Pallewatte Aruna S, Shaaban Mohamed, Shelly Esti, Stepanyan Karapet, Teo Eu-Leong Harvey J, Thelsy Naw, Visrutaratna Pannee, Zaman Areesha, Zontar Dejan. IAEA survey of pediatric CT practice in 40 countries in Asia, Europe, Latin America, and Africa: Part 1, frequency and appropriateness.. AJR. American journal of roentgenology. 2012. DOI: 10.2214/ajr.11.7273.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.