MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00784-020-03398-y

Медицинская библиотека · Clinical oral investigations · 2020

Influence of bone density, drill diameter, drilling speed, and irrigation on temperature changes during implant osteotomies: an in vitro study.

Salomó-Coll Oscar, Auriol-Muerza Beatriz, Lozano-Carrascal Naroa, Hernández-Alfaro Federico, Wang Hom-Lay, Gargallo-Albiol Jordi

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The aim of this in vitro study was to evaluate the influence of bone type, drill diameter, drilling speed, and irrigation on heat generation while performing osteotomy for dental implants.

MATERIALS AND

METHODS

Six polyurethane foam blocks simulating type I (dense) and type IV (soft) bone were selected for the study. Each block was subjected to two different experimental conditions for each drill (2- and 3.5-mm diameter): three sub-groups were created: (a) revolutions per minute (50, 100, or 800 rpm) and (b) irrigation (with or without irrigation).

RESULTS

In 2-mm drill group, maximum temperature attained was practically identical: 23.73 ± 2.28 °C in the cortical bone and 23.74 ± 2.03 °C in the cancellous bone. For 3.5-mm, groups showed similar results (25.01 ± 1.88 °C for cortical and 24.05 ± 1.94 °C for trabecular bone). In any type of bone, the presence of irrigating fluid helped to control the maximum temperature (p = 0.001). When comparing the 2-mm and 3.5-mm drills, most differences were found at 100 rpm without irrigation (p < 0.001) and at 800 rpm with irrigation (p = 0.001).

CONCLUSIONS

Maximum temperature attained was always below the critical threshold that can cause osteonecrosis, showing that both external irrigation with higher drilling speeds and no irrigation with lower speeds were effective methods to avoid excessive heat generation.

CLINICAL RELEVANCE: Despite being always below the critical temperature, bone type, drill diameter, drilling speed, and irrigation must be considered temperature-influencing factors during implant osteotomies.

Для цитирования: Salomó-Coll Oscar, Auriol-Muerza Beatriz, Lozano-Carrascal Naroa, Hernández-Alfaro Federico, Wang Hom-Lay, Gargallo-Albiol Jordi. Influence of bone density, drill diameter, drilling speed, and irrigation on temperature changes during implant osteotomies: an in vitro study.. Clinical oral investigations. 2020. DOI: 10.1007/s00784-020-03398-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.