MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/15589447211052756

Медицинская библиотека · Hand (New York, N.Y.) · 2021

Novel Use of an Internal Distractor for Metacarpal Lengthening.

Bashour Laura E, Hill Charles, Frommer Sarah A, Henry Steven L

СтатьяПеревод в очереди

Аннотация

BACKGROUND

In patients who have had proximal digit amputation, metacarpal distraction osteogenesis is an option to improve digital length and function. One drawback is that traditional external distraction devices are large and cumbersome; the option of a low-profile internal device is therefore appealing. Internal distractors are commonly used in craniofacial reconstruction, but use in the hand has not been reported. We describe a case series of the novel use of an internal distractor in metacarpal lengthening.

METHODS

In this single-center case series, patients who underwent metacarpal distraction by the senior author using a uniplanar internal distractor were reviewed, and indications, outcomes, and complications were analyzed.

RESULTS

There were 5 cases in 4 patients (age range: 7-33 years). Indications were traumatic amputation in 4 cases and congenital hypoplasia in 1. All were successfully distracted, with a mean final length gain of 1.3 cm (range: 1.0-1.7 mm). Mean time from device placement to consolidation was 3.5 months. Complications included activation arm site infection in 2 cases, both occurring after the distraction period, necessitating device removal before full consolidation. In these cases, the device was removed after the distraction period and replaced with a Kirschner wire for stabilization through the consolidation period.

CONCLUSIONS

Metacarpal distraction was successfully achieved with an internal distraction device. Although infection was common, it occurred after the distraction period and did not preclude length gain. We feel that this low-profile device offers advantages over cumbersome external devices typically used for metacarpal lengthening.

Для цитирования: Bashour Laura E, Hill Charles, Frommer Sarah A, Henry Steven L. Novel Use of an Internal Distractor for Metacarpal Lengthening.. Hand (New York, N.Y.). 2021. DOI: 10.1177/15589447211052756.