MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-025-31883-5

Медицинская библиотека · Scientific reports · 2025

Reliable wrist PPG monitoring by mitigating poor skin sensor contact.

Pham Hung Manh, Ho Matthew Yiwen, Zhang Yiming, Spathis Dimitris, Saeed Aaqib, Ma Dong

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Photoplethysmography (PPG) is a widely used non-invasive technique for monitoring cardiovascular health and various physiological parameters on consumer and medical devices. While motion artifacts are well-known challenges in dynamic settings, suboptimal skin-sensor contact in sedentary conditions - an important issue often overlooked in existing literature - can distort PPG signal morphology, leading to the loss or shift of essential waveform features and therefore degrading sensing performance. In this work, we propose a deep learning-based framework that transforms Contact Pressure-distorted PPG signals into ones with the ideal morphology, known as CP-PPG. CP-PPG incorporates a well-crafted data processing pipeline and an adversarially trained deep generative model, together with a custom PPG-aware loss function. We validated CP-PPG through comprehensive evaluations, including 1) morphology transformation performance, 2) downstream physiological monitoring performance on public datasets, and 3) in-the-wild performance. Extensive experiments demonstrate substantial and consistent improvements in signal fidelity (Mean Absolute Error: 0.09, 40% improvement over the original signal) as well as downstream performance across all evaluations in Heart Rate (HR), Heart Rate Variability (HRV), Respiration Rate (RR), and Blood Pressure (BP) estimation (on average, 21% improvement in HR; 41-46% in HRV; 6% in RR; and 4-5% in BP). These findings highlight the critical importance of addressing skin-sensor contact issues for accurate and reliable PPG-based physiological monitoring. Our implementation is publicly available at: https://github.com/manhph2211/CP-PPG .

Для цитирования: Pham Hung Manh, Ho Matthew Yiwen, Zhang Yiming, Spathis Dimitris, Saeed Aaqib, Ma Dong. Reliable wrist PPG monitoring by mitigating poor skin sensor contact.. Scientific reports. 2025. DOI: 10.1038/s41598-025-31883-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.